Operating Room Fomites as Potential Sources for Microbial Transmission in Burns Theatres
European Burn Journal · 06.01.2021 · 2 (1) · 1-8
DOI: 10.3390/ebj2010001 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Burn Journal, online erschienen am 06.01.2021. Verfasst von Mariam Rela und 6 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CW+.
Abstract (Originalsprache)
Background
Burn patients are susceptible to healthcare-associated infections. Contaminated surfaces play a role in microbial transmission. This study aimed to quantify the degree of contamination of burns theatre fomites during routine clinical use.
Methods
The Patslide Patient Transfer Board (PAT slide) and operating table were investigated using two methods—bacterial swabs to culture viable organisms and adenosine triphosphate (ATP) swabs to measure biological material. Both items were sampled four times a day: before the first case, immediately after a case, immediately before the next case after cleaning and after the terminal clean.
Results
Among 82 bacterial samples, four organisms were isolated, including Staphylococcus aureus, Enterobacter cloacae (E. cloacae) x2 and Pseudomonas aeruginosa (P. aeruginosa), all from the PAT slide. The E. cloacae persisted after cleaning. In 9/82 swabs, the ATP count was >10 relative light units (RLU). In all cases where an organism was identified, the ATP count was >10 RLU. Hence the sensitivity and specificity of ATP > 10 RLU in detecting an organism were 100% and 94% respectively.
Conclusions
Within burns theatres, there are instances of bacterial contamination on surfaces that persist despite cleaning. ATP luminometers as a point-of-care device may have a role in determining the cleanliness of surfaces, potentially minimizing onwards-bacterial transmission.
Förderung
- CW+
Zitieren
APA
Rela, M., Opel, S., Williams, S., Collins, D. P., Martin, K., Mughal, N., & Moore, L. S. P. (2021). Operating Room Fomites as Potential Sources for Microbial Transmission in Burns Theatres. European Burn Journal, 2(1), 1-8. https://doi.org/10.3390/ebj2010001
Vancouver
Rela M, Opel S, Williams S, Collins DP, Martin K, Mughal N, et al. Operating Room Fomites as Potential Sources for Microbial Transmission in Burns Theatres. European Burn Journal. 2021;2(1):1-8. doi:10.3390/ebj2010001
BibTeX
@article{Rela2021,
author = {Rela, Mariam and Opel, Sophia and Williams, Sarah and Collins, Declan P. and Martin, Kevin and Mughal, Nabeela and Moore, Luke S. P.},
title = {Operating Room Fomites as Potential Sources for Microbial Transmission in Burns Theatres},
journal = {European Burn Journal},
year = {2021},
volume = {2},
number = {1},
pages = {1--8},
doi = {10.3390/ebj2010001}
}