Thermodynamic Performance Analysis and Refrigerant Evaluation of Enhanced Cascade Vapor-Injection Refrigeration Systems
Entropy · 01.07.2026 · 28 (7) · 747
DOI: 10.3390/e28070747 ↗Kurz gefasst
Fachartikel in der Zeitschrift Entropy, online erschienen am 01.07.2026. Verfasst von Jidong Li und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Automation Science and Electrical Engineering, Beihang University, Beijing 100191, China. Die Arbeit nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities, Beijing Outstanding Young Scientists Program.
Abstract (Originalsprache)
To enhance the compression efficiency and refrigerant flow capacity for low-temperature refrigeration applications, the vapor-injection strategy is innovatively synthesized with two-stage cascade refrigeration systems. Two cascade vapor-injection configurations with subcoolers and flash tanks (CSVIRS and CFVIRS) are compared with the conventional cascade refrigeration system (CCRS) through integrated thermodynamic simulations. The impacts of crucial temperature and injection parameters are comprehensively analyzed through energy and exergy methods, while the performance comparisons of various refrigerant combinations are also conducted. The coefficient of performance (COP) of the CFVIRS exceeds that of the CCRS and CSVIRS by 33.84% and 2.10% under the default condition. The cascade vapor-injection configurations exhibit a performance advantage at higher condensation temperature and lower evaporation temperature of the low-temperature cycle (LTC). The evaporation temperature of the high-temperature cycle (HTC) and injection pressures are examined with optimum solutions. Decreasing the entrainment ratio of the HTC and increasing the entrainment ratio of the LTC within appropriate ranges are beneficial for the refrigeration performance. R1270-R170 demonstrates superior energy and exergy performance, whereas R143a-R23 shows the highest improvement ratio among the compared refrigerants. The implementation of cascade vapor injection substantially reduces exergy destruction in the compression and expansion devices, while the exergy characteristics of various refrigerant pairs are extensively investigated.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Automation Science and Electrical Engineering, Beihang University, Beijing 100191, China.
- Pneumatic and Thermodynamic Energy Storage and Supply Beijing Key Laboratory, Beijing 100191, China.
- School of Physics and Electronics, Henan University, Kaifeng 475004, China.
ORCID-Profile: Maolin Cai, Guanwei Jia
Förderung
- National Natural Science Foundation of China
- Fundamental Research Funds for the Central Universities
- Beijing Outstanding Young Scientists Program
Zitieren
APA
Li, J., Cai, M., Xu, W., & Jia, G. (2026). Thermodynamic Performance Analysis and Refrigerant Evaluation of Enhanced Cascade Vapor-Injection Refrigeration Systems. Entropy, 28(7), 747. https://doi.org/10.3390/e28070747
Vancouver
Li J, Cai M, Xu W, Jia G. Thermodynamic Performance Analysis and Refrigerant Evaluation of Enhanced Cascade Vapor-Injection Refrigeration Systems. Entropy. 2026;28(7):747. doi:10.3390/e28070747
BibTeX
@article{Li2026,
author = {Li, Jidong and Cai, Maolin and Xu, Weiqing and Jia, Guanwei},
title = {Thermodynamic Performance Analysis and Refrigerant Evaluation of Enhanced Cascade Vapor-Injection Refrigeration Systems},
journal = {Entropy},
year = {2026},
volume = {28},
number = {7},
pages = {747},
doi = {10.3390/e28070747}
}
EUVIMED