EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Exergoeconomic Analysis and Optimization of a Biomass Integrated Gasification Combined Cycle Based on Externally Fired Gas Turbine, Steam Rankine Cycle, Organic Rankine Cycle, and Absorption Refrigeration Cycle

Jie Ren iD, Chen Xu iD, Zuoqin Qian, Weilong Huang, Baolin Wang

Entropy · 12.06.2024 · 26 (6) · 511

DOI: 10.3390/e26060511 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Entropy, online erschienen am 12.06.2024. Verfasst von Jie Ren und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Naval Architecture, Ocean and Energy Power Engineering, Wuhan University of Technology, Wuhan 430063, China. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hubei Province Technological Innovation Special Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Adopting biomass energy as an alternative to fossil fuels for electricity production presents a viable strategy to address the prevailing energy deficits and environmental concerns, although it faces challenges related to suboptimal energy efficiency levels. This study introduces a novel combined cooling and power (CCP) system, incorporating an externally fired gas turbine (EFGT), steam Rankine cycle (SRC), absorption refrigeration cycle (ARC), and organic Rankine cycle (ORC), aimed at boosting the efficiency of biomass integrated gasification combined cycle systems. Through the development of mathematical models, this research evaluates the system’s performance from both thermodynamic and exergoeconomic perspectives. Results show that the system could achieve the thermal efficiency, exergy efficiency, and levelized cost of exergy (LCOE) of 70.67%, 39.13%, and 11.67 USD/GJ, respectively. The analysis identifies the combustion chamber of the EFGT as the component with the highest rate of exergy destruction. Further analysis on parameters indicates that improvements in thermodynamic performance are achievable with increased air compressor pressure ratio and gas turbine inlet temperature, or reduced pinch point temperature difference, while the LCOE can be minimized through adjustments in these parameters. Optimized operation conditions demonstrate a potential 5.7% reduction in LCOE at the expense of a 2.5% decrease in exergy efficiency when compared to the baseline scenario.

Schlagwörter

Stichwörter der Autor:innen

absorption refrigeration cyclebiomass gasificationcombined cooling and powerexergoeconomic analysisexternally fired gas turbinemulti-objective optimization

Autor:innen und Institutionen

  • School of Naval Architecture, Ocean and Energy Power Engineering, Wuhan University of Technology, Wuhan 430063, China.

ORCID-Profile: Jie Ren, Chen Xu

Förderung

  • Hubei Province Technological Innovation Special Fund

Zitieren

APA

Ren, J., Xu, C., Qian, Z., Huang, W., & Wang, B. (2024). Exergoeconomic Analysis and Optimization of a Biomass Integrated Gasification Combined Cycle Based on Externally Fired Gas Turbine, Steam Rankine Cycle, Organic Rankine Cycle, and Absorption Refrigeration Cycle. Entropy, 26(6), 511. https://doi.org/10.3390/e26060511

Vancouver

Ren J, Xu C, Qian Z, Huang W, Wang B. Exergoeconomic Analysis and Optimization of a Biomass Integrated Gasification Combined Cycle Based on Externally Fired Gas Turbine, Steam Rankine Cycle, Organic Rankine Cycle, and Absorption Refrigeration Cycle. Entropy. 2024;26(6):511. doi:10.3390/e26060511

BibTeX
@article{Ren2024,
  author = {Ren, Jie and Xu, Chen and Qian, Zuoqin and Huang, Weilong and Wang, Baolin},
  title = {Exergoeconomic Analysis and Optimization of a Biomass Integrated Gasification Combined Cycle Based on Externally Fired Gas Turbine, Steam Rankine Cycle, Organic Rankine Cycle, and Absorption Refrigeration Cycle},
  journal = {Entropy},
  year = {2024},
  volume = {26},
  number = {6},
  pages = {511},
  doi = {10.3390/e26060511}
}
Kostenlos starten →