Sterilization Effect on Axes and Distances Between Three Implants in Curved Lines When Using Two Types of Two-Piece Intra-Oral Scan Bodies: An In Vitro Study
Dentistry Journal · 06.08.2026 · 14 (8) · 491
DOI: 10.3390/dj14080491 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentistry Journal, online erschienen am 06.08.2026. Verfasst von Ofir Rosner und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Gray Faculty of Medical & Health Sciences, Tel Av…. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The aim of this in vitro study was to examine the effect of the sterilization process on two different two-piece intra-oral scan bodies (ISBs) using three-dimensional (3D) analysis.
Methods
Two identical 3D-printed models with three analogs in positions #12, #13, and 14# were used: two-piece titanium (Ti-Ti) and two-piece poly-ether-ether-ketone (PEEK) and Ti (PEEK-Ti) ISBs. Each model was scanned once before sterilization. A laboratory scanner (LBS) produced a reference stereolithography (STL) file, followed by 30 scans with an intra-oral scanner (IOS), producing 30 STL files. Both ISBs underwent three cycles of sterilization followed by thirty scans using an IOS, producing another 30 STL files. Each STL file was superimposed on the LBS reference STL file using 3D analyzing software, and the following parameters were calculated: inter-implant distance, intra-implant distance, inter-implant angle, and intra-implant angle. The Kolmogorov–Smirnov test indicated non-normal distribution; therefore, Wilcoxon signed-rank tests and Mann–Whitney tests were performed (p < 0.05).
Results
Within groups, after sterilization, the mean errors of the Ti-Ti ISB were significantly increased regarding inter-implant distance 12_13 (p < 0.05), intra-implant distance 14 (p = 0.0005), inter-implant angle 12_13 (p = 0.0005), inter-implant angle 13_14 (p = 0.001), intra-implant angle 13 (p = 0.005), and intra-implant angle 14 (p < 0.05). Within groups, after sterilization, the mean errors of the PEEK-Ti ISB were significantly increased regarding inter-implant distance 12_13, 13_14, and 12_14 (p = 0.0005), intra-implant distance 12 (p < 0.05), intra-implant distance 13 and 14 (p = 0.0005), inter-implant angle 12_13 (p = 0.0005), and inter-implant angle 13_14 (p = 0.005). Between groups, after sterilization, the mean errors for the PEEK-Ti ISB were significantly higher (p < 0.0005) regarding all parameters compared to the Ti-Ti ISB.
Conclusions
Both PEEK-Ti and Ti-Ti ISBs showed significant changes in most parameters after three cycles of sterilization, with the PEEK-Ti ISB exhibiting greater changes compared to the Ti-Ti ISB. Therefore, three cycles of sterilization affect axes and distances for both PEEK-Ti and Ti-Ti ISBs.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Gray Faculty of Medical & Health Sciences, Tel Aviv University, Tel Aviv 6997801, Israel.
- Department of Orthodontics, The Maurice and Gabriela Goldschleger School of Dental Medicine, Gray Faculty of Medical & Health Sciences, Tel Aviv University, Tel Aviv 699780, Israel.
- Dental Division, Shamir (Assaf Harofeh) Medical Center, Beer Yaacov 70300, Israel.
ORCID-Profile: Yifat Manor, Gil Ben-Izhack
Zitieren
APA
Rosner, O., Katz, A. P., Nissan, J., Aghov, E. S., Lugassy, D., Manor, Y., & Ben-Izhack, G. (2026). Sterilization Effect on Axes and Distances Between Three Implants in Curved Lines When Using Two Types of Two-Piece Intra-Oral Scan Bodies: An In Vitro Study. Dentistry Journal, 14(8), 491. https://doi.org/10.3390/dj14080491
Vancouver
Rosner O, Katz AP, Nissan J, Aghov ES, Lugassy D, Manor Y, et al. Sterilization Effect on Axes and Distances Between Three Implants in Curved Lines When Using Two Types of Two-Piece Intra-Oral Scan Bodies: An In Vitro Study. Dentistry Journal. 2026;14(8):491. doi:10.3390/dj14080491
BibTeX
@article{Rosner2026,
author = {Rosner, Ofir and Katz, Adar Polonsky and Nissan, Joseph and Aghov, Ela Shir and Lugassy, Diva and Manor, Yifat and Ben-Izhack, Gil},
title = {Sterilization Effect on Axes and Distances Between Three Implants in Curved Lines When Using Two Types of Two-Piece Intra-Oral Scan Bodies: An In Vitro Study},
journal = {Dentistry Journal},
year = {2026},
volume = {14},
number = {8},
pages = {491},
doi = {10.3390/dj14080491}
}
EUVIMED