Kohortenstudie in der Zeitschrift Dentistry Journal, online erschienen am 16.07.2026. Verfasst von Nicola De Angelis und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, 16126 Genova, Italy. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
To compare the short-term clinical and radiographic outcomes of electrolytic versus conventional mechanical implant surface decontamination during surgical treatment of peri-implantitis.
Methods
This retrospective cohort study included 20 implants affected by peri-implantitis in 20 patients. Ten implants were treated using electrolytic implant surface decontamination, while 10 implants received conventional mechanical decontamination with titanium curettes, chitosan brushes, and glycine powder air-polishing. In addition, regenerative therapy of the peri-implant defect was performed in 8 of the 20 treated sites, equally distributed between the two groups (4 sites per group). Clinical and radiographic parameters, including probing depth (PD) and radiographic bone loss, were assessed at baseline and after 6 months. Intragroup and intergroup comparisons were performed using parametric statistical analyses (α = 0.05).
Results
Both treatment protocols resulted in statistically significant improvements in probing depth reduction and radiographic bone fill after 6 months (p < 0.001). In the electrolytic group, mean PD decreased from 6.7 ± 0.95 mm to 4.0 ± 0.2 mm, while in the conventional group, PD decreased from 6.8 ± 1.03 mm to 3.3 ± 0.3 mm. Radiographic bone loss decreased from 4.88 ± 0.70 mm to 0.94 ± 0.70 mm in the electrolytic group and from 4.88 ± 1.83 mm to 0.94 ± 1.14 mm in the conventional group. No statistically significant intergroup differences were observed for probing depth reduction or radiographic bone level changes. No implant losses occurred during the observation period.
Conclusions
Within the limitations of this retrospective study, both electrolytic and conventional mechanical implant surface decontamination protocols resulted in significant short-term clinical and radiographic improvements following peri-implantitis surgery. Electrolytic cleaning demonstrated outcomes comparable to conventional therapy and may represent a viable alternative for implant surface decontamination.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, 16126 Genova, Italy.
- Private Practice, 15011 Acqui Terme, Italy.
ORCID-Profile: Paolo Pesce, Esteban Colombo, Maria Menini
Zitieren
APA
De Angelis, N., Pesce, P., Santamaria, G., Colombo, E., Yumang, C., & Menini, M. (2026). Clinical and Radiographic Outcomes of Electrolytic Implant Surface Decontamination in Peri-Implantitis Surgery: A Retrospective Cohort Study. Dentistry Journal, 14(7), 447. https://doi.org/10.3390/dj14070447
Vancouver
De Angelis N, Pesce P, Santamaria G, Colombo E, Yumang C, Menini M. Clinical and Radiographic Outcomes of Electrolytic Implant Surface Decontamination in Peri-Implantitis Surgery: A Retrospective Cohort Study. Dentistry Journal. 2026;14(7):447. doi:10.3390/dj14070447
BibTeX
@article{DeAngelis2026,
author = {De Angelis, Nicola and Pesce, Paolo and Santamaria, Giulia and Colombo, Esteban and Yumang, Catherine and Menini, Maria},
title = {Clinical and Radiographic Outcomes of Electrolytic Implant Surface Decontamination in Peri-Implantitis Surgery: A Retrospective Cohort Study},
journal = {Dentistry Journal},
year = {2026},
volume = {14},
number = {7},
pages = {447},
doi = {10.3390/dj14070447}
}
EUVIMED