EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Predictability of In-Office SureSmile® Clear Aligners: A Retrospective Analysis of Anterior Tooth Movements

Gina Marie Georgi, Jesper Delfs, Cita Nottmeier, Bärbel Kahl-Nieke, Maija Eltz, Matthias Sonnleitner, Till Koehne, Carmen U Schmid-Herrmann

Dentistry Journal · 15.06.2026 · 14 (6) · 370

DOI: 10.3390/dj14060370 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Dentistry Journal, online erschienen am 15.06.2026. Verfasst von Gina Marie Georgi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, University Medical Center Leipzig, Liebigstraße 12, 04103 Leipzig, Germany. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Aligner workflows range from outsourcing the design and manufacturing process to in-office scanning, planning, and fabrication. This exploratory retrospective study aimed to evaluate whether discrepancies between planned and achieved anterior tooth movements with SureSmile aligners remain within predefined clinical thresholds.

Methods

A total of 21 dental arches from 14 patients who underwent SureSmile aligner treatment with in-office fabricated aligners were retrospectively analyzed. Digital models of the planned setup were superimposed on models of the clinically achieved outcomes to assess the accuracy of anterior tooth movements by comparing planned and clinically achieved outcomes.

Results

Rotational movements showed larger discrepancies than translational movements. Mean discrepancies for angulation and axial rotation were 3.42 ± 1.50° and 4.50 ± 2.12°, respectively, both exceeding the predefined clinical threshold of 2°. In contrast, translational discrepancies remained below the clinical threshold of 0.5 mm, with mean values of 0.17 ± 0.11 mm for mesiodistal, 0.27 ± 0.16 mm for labiolingual, and 0.38 ± 0.17 mm for vertical movements. Translational discrepancies were significantly lower than the predefined clinical threshold in patient-level analyses, whereas rotational discrepancies were not.

Conclusions

In-office SureSmile aligner workflows showed acceptable accuracy for translational anterior tooth movements, whereas angular movements frequently exceeded predefined clinical thresholds.

Schlagwörter

Stichwörter der Autor:innen

SureSmilealigner treatment accuracyanterior tooth movement

Autor:innen und Institutionen

  • Department of Orthodontics, University Medical Center Leipzig, Liebigstraße 12, 04103 Leipzig, Germany.
  • Private Orthodontic Practice Kiefer & Zahn, Kücknitzer Hauptstraße 2, 23569 Lubeck, Germany.
  • Department of Orthodontics, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg, Germany.
  • Private Orthodontic Practice Eltz Institut für Kieferorthopädie, 1010 Vienna, Austria.
  • Private Orthodontic Practice Ruperti-Kieferorthopädie, Rottmayrstraße 3, 83410 Laufen, Germany.

Zitieren

APA

Georgi, G. M., Delfs, J., Nottmeier, C., Kahl-Nieke, B., Eltz, M., Sonnleitner, M., Koehne, T., & Schmid-Herrmann, C. U. (2026). Predictability of In-Office SureSmile® Clear Aligners: A Retrospective Analysis of Anterior Tooth Movements. Dentistry Journal, 14(6), 370. https://doi.org/10.3390/dj14060370

Vancouver

Georgi GM, Delfs J, Nottmeier C, Kahl-Nieke B, Eltz M, Sonnleitner M, et al. Predictability of In-Office SureSmile® Clear Aligners: A Retrospective Analysis of Anterior Tooth Movements. Dentistry Journal. 2026;14(6):370. doi:10.3390/dj14060370

BibTeX
@article{Georgi2026,
  author = {Georgi, Gina Marie and Delfs, Jesper and Nottmeier, Cita and Kahl-Nieke, Bärbel and Eltz, Maija and Sonnleitner, Matthias and Koehne, Till and Schmid-Herrmann, Carmen U},
  title = {Predictability of In-Office SureSmile® Clear Aligners: A Retrospective Analysis of Anterior Tooth Movements},
  journal = {Dentistry Journal},
  year = {2026},
  volume = {14},
  number = {6},
  pages = {370},
  doi = {10.3390/dj14060370}
}
Kostenlos starten →