Cytotoxicity of Self-Etch Versus Etch-and-Rinse Dentin Adhesives After 48 h: An In Vitro Study
Dentistry Journal · 19.05.2026 · 14 (5) · 312
DOI: 10.3390/dj14050312 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentistry Journal, online erschienen am 19.05.2026. Verfasst von Kamelia Parkhoo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Operative Dentistry, Carolinum, Goethe University Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany. Die Arbeit nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
Six dentin adhesives were tested in vitro regarding their cytotoxicity toward human fibroblasts. AdheSE, Clearfil SE Bond, Hybrid Bond, One-up Bond F Plus, Optibond Solo Plus, and Syntac were tested using a cell culture model. The several components of dentin adhesives, like the primer and bonding, were analyzed as single and additive applied components as specified by the manufacturer for application in vivo.
Methods
Seventy-five Petri dishes were produced per adhesive and control group, and all 525 Petri dishes were evaluated using multiparametric strategies, i.e., using multiple methods to strengthen the reliability of the results. The multiparametric strategies consisted of automated cell counting for viability, microscopic morphological assessment and lastly of reactivity grading according to ISO 10993-5. These assessments were performed after our initial investigation, and the observation period was extended from 24 h to 48 h.
Results
AdheSE, Clearfil SE Bond, One-up Bond F Plus, and Optibond Solo Plus showed statistically significant reductions in viable cells relative to the cell control. All dentin adhesives except Clearfil SE Bond showed a statistically significant difference regarding the reactivity index in the application comparison.
Conclusions
The test materials showed a moderate degree of cytotoxicity, with no statistically significant difference between the tested self-etch and etch-and-rinse dentin adhesives. However, the results show statistically significant differences between the adhesives when applied sequentially and once. Further research addressing mechanisms of cytotoxicity is needed for advancement in this field.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Operative Dentistry, Carolinum, Goethe University Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.
- Department of Oral Surgery and Implant Dentistry and Oral Medicine, Carolinum, Goethe University Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.
- Institute of Biostatistics and Mathematical Modelling, Goethe University, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.
ORCID-Profile: Georgios E Romanos, Eva Herrmann
Zitieren
APA
Parkhoo, K., Schmitz, L. A., Fröb, L., Grüßner, N., Romanos, G. E., Herrmann, E., & Gerhardt-Szép, S. (2026). Cytotoxicity of Self-Etch Versus Etch-and-Rinse Dentin Adhesives After 48 h: An In Vitro Study. Dentistry Journal, 14(5), 312. https://doi.org/10.3390/dj14050312
Vancouver
Parkhoo K, Schmitz LA, Fröb L, Grüßner N, Romanos GE, Herrmann E, et al. Cytotoxicity of Self-Etch Versus Etch-and-Rinse Dentin Adhesives After 48 h: An In Vitro Study. Dentistry Journal. 2026;14(5):312. doi:10.3390/dj14050312
BibTeX
@article{Parkhoo2026,
author = {Parkhoo, Kamelia and Schmitz, Lea Aylin and Fröb, Luisa and Grüßner, Nicole and Romanos, Georgios E and Herrmann, Eva and Gerhardt-Szép, Susanne},
title = {Cytotoxicity of Self-Etch Versus Etch-and-Rinse Dentin Adhesives After 48 h: An In Vitro Study},
journal = {Dentistry Journal},
year = {2026},
volume = {14},
number = {5},
pages = {312},
doi = {10.3390/dj14050312}
}
EUVIMED