Effect of Pre-Setting Exposure to 17% EDTA on Physicochemical and Surface Properties of AH Plus Bioceramic and AH Plus Endodontic Sealers
Dentistry Journal · 24.03.2026 · 14 (4) · 191
DOI: 10.3390/dj14040191 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentistry Journal, online erschienen am 24.03.2026. Verfasst von Gerardo Alberto Salvador Gomez-Lara und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Dentistry, Autonomous University of Tamaulipas, Av. Universidad Esq. con Blvd, Adolfo Lopez Mateos S/N, Tampico C.P. 89337, Tamaulipas, Me…. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: Residual EDTA may persist after smear-layer removal and after the application of contact sealers during setting. This in vitro study compared the effect of 1 min of pre-setting surface contact with 17% EDTA (vs. distilled water) on a calcium silicate-based sealer (AH Plus Bioceramic Sealer) and an epoxy resin-based sealer (AH Plus).
Methods
Discs were prepared (N = 108) in a 2 × 2 design (n = 27/group); per group; n = 12 were used for solubility followed by eluate pH using the same specimens/eluates after 24 h immersion in distilled water; n = 12 were used to test Vickers microhardness on an independent set after setting; and n = 3 were used for SEM/EDS.
Results
Data were analyzed at α = 0.05 using Kruskal–Wallis tests followed by Bonferroni-adjusted pairwise Mann–Whitney U tests for solubility and eluate pH, and one-way ANOVA was performed followed by Tukey’s post hoc test to assess the microhardness. Solubility differed among groups (p < 0.001) and was higher for the bioceramic sealer than for the resin sealer; pre-setting EDTA exposure increased solubility for the AH Plus Bioceramic Sealer (0.86 ± 0.08% to 1.30 ± 0.16%) and decreased solubility for AH Plus (0.34 ± 0.04% to 0.22 ± 0.03%) (p < 0.05). The eluate pH also differed among groups (p = 0.001) and was higher for the bioceramic sealer (≈11.7) than for the resin sealer (≈8.7–9.3), with no within-material differences (p = 0.999 and p = 0.851). Microhardness differed among groups (p < 0.001) and was higher for AH Plus (239.70–246.92 HV) than for AH Plus Bioceramic (131.72–170.83 HV); EDTA reduced microhardness only for the bioceramic sealer (p < 0.001), with no significant change for AH Plus (p = 0.475). Descriptive SEM/EDS findings suggested increased surface irregularities and lower surface Ca for AH Plus Bioceramic after EDTA exposure (12.68 to 7.31 wt%).
Conclusions
Pre-setting EDTA contact therefore produced material-dependent changes in early properties and adverse surface-related effects in the calcium silicate-based sealer, supporting thorough chelator removal before obturation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Dentistry, Autonomous University of Tamaulipas, Av. Universidad Esq. con Blvd, Adolfo Lopez Mateos S/N, Tampico C.P. 89337, Tamaulipas, Mexico.
Zitieren
APA
Gomez-Lara, G. A. S., Luna-Lara, C. A., Oliver-Parra, R., Oliver-Parra, S. S., Luna-Dominguez, C. R., & Luna-Dominguez, J. H. (2026). Effect of Pre-Setting Exposure to 17% EDTA on Physicochemical and Surface Properties of AH Plus Bioceramic and AH Plus Endodontic Sealers. Dentistry Journal, 14(4), 191. https://doi.org/10.3390/dj14040191
Vancouver
Gomez-Lara GAS, Luna-Lara CA, Oliver-Parra R, Oliver-Parra SS, Luna-Dominguez CR, Luna-Dominguez JH. Effect of Pre-Setting Exposure to 17% EDTA on Physicochemical and Surface Properties of AH Plus Bioceramic and AH Plus Endodontic Sealers. Dentistry Journal. 2026;14(4):191. doi:10.3390/dj14040191
BibTeX
@article{GomezLara2026,
author = {Gomez-Lara, Gerardo Alberto Salvador and Luna-Lara, Carlos Alberto and Oliver-Parra, Rogelio and Oliver-Parra, Suria Sarahi and Luna-Dominguez, Carlos Roberto and Luna-Dominguez, Jorge Humberto},
title = {Effect of Pre-Setting Exposure to 17% EDTA on Physicochemical and Surface Properties of AH Plus Bioceramic and AH Plus Endodontic Sealers},
journal = {Dentistry Journal},
year = {2026},
volume = {14},
number = {4},
pages = {191},
doi = {10.3390/dj14040191}
}
EUVIMED