Biocompatibility Evaluation of Novel Experimental Titanium Alloys for Dental Implants
Dentistry Journal · 22.12.2025 · 14 (1) · 6
DOI: 10.3390/dj14010006 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentistry Journal, online erschienen am 22.12.2025. Verfasst von Vlad-Gabriel Vasilescu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Discipline of Dental Prosthesis Technology, Faculty of Dentistry, "Carol Davila" University of Medicine and Pharmacy, Dionisie Lupu Street, No. 37, D…. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 80 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: The purpose of this study was to assess the in vitro biocompatibility and corrosion resistance of five titanium alloys that have been recently developed for dental implant applications, whose compositions were designed to align with current approaches in the development of novel biomaterials. Priority was given to limiting the harmfulness associated with specific chemical elements present in common conventional alloys and increasing corrosion resistance to improve the biomaterial–tissue cellular interaction.
Methods
For this purpose, five types of titanium alloys with original chemical compositions (Ti1–Ti5) were developed. The electrochemical behavior of the alloys was analyzed by evaluating the corrosion resistance in environments that simulate the oral environment, as well as the cellular behavior, by evaluating the viability, growth, and proliferation of human cells on osteoblasts and gingival fibroblasts. Detailed analysis of the chemical composition by scanning electron microscope (SEM/EDS) methods was used. The corrosion rate of the alloys in artificial saliva was tested using the polarization resistance technique (Tafel). Human osteoblasts (hFOB cell line) and human gingival fibroblasts (hFIB-G cell line) were used to measure biocompatibility in vitro.
Results
The Ti5 alloy demonstrated the highest cell viability and the lowest corrosion rate (0.114 μm/year) among all tested compositions, with the Ti3 alloy containing Mo and Zr following closely behind. The Ti2 alloy exhibited reduced biocompatibility because of the inclusion of Ni and Fe in its composition.
Conclusions
Taken together, the results of this study provide useful information on the basic characteristics of titanium alloys with original chemical compositions. The titanium alloys were analyzed in comparison with common conventional alloys (Cp–Ti and Ti6Al4V) as well as alloys such as Ti–Zr, Ti–Nb, and Ti–Nb–Zr–Ta, which are considered to be viable alternatives to conventional materials for making dental implants.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Discipline of Dental Prosthesis Technology, Faculty of Dentistry, "Carol Davila" University of Medicine and Pharmacy, Dionisie Lupu Street, No. 37, District 2, 020021 Bucharest, Romania.
- Department of Biochemistry and Molecular Biology, Faculty of Biology, University of Bucharest, 9195 Splaiul Independentei, 050095 Bucharest, Romania.
- Faculty of Materials Science and Engineering, National University of Science and Technology POLITEHNICA Bucharest, Splaiul Independentei 313, J Building, 060042 Bucharest, Romania.
- General Association of Engineers in Romania (AGIR), AGIR Board of Directors, Victoriei Boulevard 118, 030167 Bucharest, Romania.
- Discipline of Prosthodontics, Faculty of Dentistry, "Carol Davila" University of Medicine and Pharmacy, 37 Dionisie Lupu Street, District 2, 020021 Bucharest, Romania.
- Department of Organization, Professional Legislation and Management of the Dental Office, Faculty of Dental Medicine, "Carol Davila" University of Medicine and Pharmacy, 17-23 Plevnei Str., 020021 Bucharest, Romania.
ORCID-Profile: Vlad-Gabriel Vasilescu, Lucian Toma Ciocan, Andreea Mihaela Custura, Miruna Stan, Florin Miculescu, Cosmin Mihai Cotrut, Diana Maria Vranceanu
Zitieren
APA
Vasilescu, V. G., Ciocan, L. T., Custura, A. M., Stan, M., Miculescu, F., Cotrut, C. M., Vranceanu, D. M., Vasilescu, E., Imre, M., & Pițuru, S. M. (2025). Biocompatibility Evaluation of Novel Experimental Titanium Alloys for Dental Implants. Dentistry Journal, 14(1), 6. https://doi.org/10.3390/dj14010006
Vancouver
Vasilescu VG, Ciocan LT, Custura AM, Stan M, Miculescu F, Cotrut CM, et al. Biocompatibility Evaluation of Novel Experimental Titanium Alloys for Dental Implants. Dentistry Journal. 2025;14(1):6. doi:10.3390/dj14010006
BibTeX
@article{Vasilescu2025,
author = {Vasilescu, Vlad-Gabriel and Ciocan, Lucian Toma and Custura, Andreea Mihaela and Stan, Miruna and Miculescu, Florin and Cotrut, Cosmin Mihai and Vranceanu, Diana Maria and Vasilescu, Elisabeta and Imre, Marina and Pițuru, Silviu Mirel},
title = {Biocompatibility Evaluation of Novel Experimental Titanium Alloys for Dental Implants},
journal = {Dentistry Journal},
year = {2025},
volume = {14},
number = {1},
pages = {6},
doi = {10.3390/dj14010006}
}
EUVIMED