EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Preliminary Assessment of a Hybrid Implant Design Submitted to Immediate Placement with Abutment Exposure: A Pilot Study in One Dog Model

Carlos Araujo iD, Maria Angelica Araujo, César Augusto Magalhães Benfatti, Anderson Camargo Moreira iD, Celso Peres Fernandes iD, Roberta Michels

Dentistry Journal · 10.10.2025 · 13 (10) · 463

DOI: 10.3390/dj13100463 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Dentistry Journal, online erschienen am 10.10.2025. Verfasst von Carlos Araujo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Faculty of Dentistry (FOP), University of São Paulo (USP), Bauru 17012-901, Brazil. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Neodent Straumann Group, Curitiba, Brazil.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Dental implants are widely used to replace missing teeth, particularly in aesthetically sensitive areas. The implant’s macrogeometry is crucial for ensuring primary stability and successful osseointegration. Internal conical connections and reactive surfaces on implants have shown positive outcomes in tissue and bone stability. In response, a hybrid conical dental implant was designed to address a variety of clinical scenarios. Materials and Methods: This pilot study evaluated the performance of the hybrid conical implant using histological and micro-CT analysis in a preclinical model with immediate loading. Five implants were placed in a mongrel dog, and histomorphometric and micro-CT assessments were performed after 60 days of healing.

Results

Analysis showed a high degree of osseointegration, with BIC at 61.56% and BT/TV at 77%. Micro-CT confirmed these findings, with nBIC at 82.20%. Vertical measurements indicated stable crestal bone. Peri-implant tissue displayed organized supracrestal connective tissue, without signs of inflammation or bone saucerization. Polarized light microscopy revealed collagen fibers in perpendicular and oblique orientations around the abutment, suggesting mechanical integration and biological sealing despite the absence of a prosthetic crown.

Conclusions

Within the limitations of this exploratory study with one animal study, the hybrid conical implant showed favorable biological and structural responses under immediate loading. These preliminary findings provide useful insights for the refinement of implant design, although further investigations in larger preclinical and clinical studies are required before clinical applicability can be confirmed.

Schlagwörter

Stichwörter der Autor:innen

animal modelhistologyimmediate dental implant loadingosseointegration

Autor:innen und Institutionen

  • Department of Prosthodontics, Faculty of Dentistry (FOP), University of São Paulo (USP), Bauru 17012-901, Brazil.
  • Latin-America for Dentistry Education and Research (ILAPEO), Curitiba 80440-020, Brazil.
  • Center for Education and Research on Dental Implants (CEPID), Post-Graduate Program in Dentistry (PPGO), Federal University of Santa Catarina (UFSC), Florianopolis 88040-900, Brazil.
  • LMPT Laboratory, Mechanical Engineering Department, Federal University of Santa Catarina (UFSC), Florianopolis 88040-900, Brazil.
  • Department of Periodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland.

ORCID-Profile: Carlos Araujo, Anderson Camargo Moreira, Celso Peres Fernandes

Förderung

  • Neodent Straumann Group, Curitiba, Brazil

Zitieren

APA

Araujo, C., Araujo, M. A., Benfatti, C. A. M., Moreira, A. C., Fernandes, C. P., & Michels, R. (2025). Preliminary Assessment of a Hybrid Implant Design Submitted to Immediate Placement with Abutment Exposure: A Pilot Study in One Dog Model. Dentistry Journal, 13(10), 463. https://doi.org/10.3390/dj13100463

Vancouver

Araujo C, Araujo MA, Benfatti CAM, Moreira AC, Fernandes CP, Michels R. Preliminary Assessment of a Hybrid Implant Design Submitted to Immediate Placement with Abutment Exposure: A Pilot Study in One Dog Model. Dentistry Journal. 2025;13(10):463. doi:10.3390/dj13100463

BibTeX
@article{Araujo2025,
  author = {Araujo, Carlos and Araujo, Maria Angelica and Benfatti, César Augusto Magalhães and Moreira, Anderson Camargo and Fernandes, Celso Peres and Michels, Roberta},
  title = {Preliminary Assessment of a Hybrid Implant Design Submitted to Immediate Placement with Abutment Exposure: A Pilot Study in One Dog Model},
  journal = {Dentistry Journal},
  year = {2025},
  volume = {13},
  number = {10},
  pages = {463},
  doi = {10.3390/dj13100463}
}
Kostenlos starten →