Air Particle Abrasion in Dentistry: An Overview of Effects on Dentin Adhesion and Bond Strength
Dentistry Journal · 29.12.2024 · 13 (1) · 16
DOI: 10.3390/dj13010016 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Dentistry Journal, online erschienen am 29.12.2024. Verfasst von Andreea Kui und 6 weiteren Autor:innen. Beteiligte Einrichtung: Prosthetic Dentistry Discipline, Department 4-Prosthodontics and Dental Materials, Faculty of Dental Medicine, "Iuliu Hațieganu" University of Medici…. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: “Iuliu Hațieganu” University of Medicine and Pharmacy.
Abstract (Originalsprache)
Background/Objectives: Air particle abrasion (APA) is a common surface preparation method in dentistry, particularly for improving bond strength to dentin. This review evaluates the influence of APA on dentin adhesion.
Methods
A systematic literature search from 2018 to 2023 was conducted according to PRISMA-ScR guidelines. Articles investigating the effects of APA on dentin adhesion using different particle types, sizes and adhesive systems were included. Data extraction included particle size, air pressure, outcomes tested and failure modes.
Results
Fourteen primary studies met the criteria. Bioactive glass showed higher bond strength and more cohesive failures than alumina. Alumina particles (50 μm) bonded effectively in etch-and-rinse adhesive systems but failed more often in self-etch systems. Silica-modified alumina and mixed abrasive systems showed improvements in bonding performance. Optimal APA parameters were identified as 50 μm particle size, 60 psi (4 bar) air pressure and 5 s exposure time. Longer exposure times provided no additional benefit. Self-etch systems showed reduced bond strength compared to etch-and-rinse systems.
Conclusions
This review looks at how particle type, size and air pressure affect dentin adhesion. Bioactive glass is a superior material due to its bond strength and reduced cytotoxicity. The optimal APA parameters are 50 μm particle size, 60 psi and 5 s. Etch-and-rinse systems are recommended for optimal adhesion. Further research is required on APA protocols and long-term durability.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Prosthetic Dentistry Discipline, Department 4-Prosthodontics and Dental Materials, Faculty of Dental Medicine, "Iuliu Hațieganu" University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania.
- Dental Materials Discipline, Department 4-Prosthodontics and Dental Materials, Faculty of Dental Medicine, "Iuliu Hațieganu" University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania.
- Cluj County Emergency Clinical Hospital, 400347 Cluj-Napoca, Romania.
ORCID-Profile: Andreea Kui, Smaranda Buduru, Sorina Sava
Förderung
- “Iuliu Hațieganu” University of Medicine and Pharmacy
Zitieren
APA
Kui, A., Buduru, S., Labuneț, A., Sava, S., Pop, D., Bara, I., & Negucioiu, M. (2024). Air Particle Abrasion in Dentistry: An Overview of Effects on Dentin Adhesion and Bond Strength. Dentistry Journal, 13(1), 16. https://doi.org/10.3390/dj13010016
Vancouver
Kui A, Buduru S, Labuneț A, Sava S, Pop D, Bara I, et al. Air Particle Abrasion in Dentistry: An Overview of Effects on Dentin Adhesion and Bond Strength. Dentistry Journal. 2024;13(1):16. doi:10.3390/dj13010016
BibTeX
@article{Kui2024,
author = {Kui, Andreea and Buduru, Smaranda and Labuneț, Anca and Sava, Sorina and Pop, Dalia and Bara, Iris and Negucioiu, Marius},
title = {Air Particle Abrasion in Dentistry: An Overview of Effects on Dentin Adhesion and Bond Strength},
journal = {Dentistry Journal},
year = {2024},
volume = {13},
number = {1},
pages = {16},
doi = {10.3390/dj13010016}
}
EUVIMED