Background/Objectives: The right ventricular ejection fraction (RVEF) is used with clinical thresholds, and deep learning models measure it after training on expert contours (labels). When these labels are refined, the models are re-evaluated by contour overlap. However, the overlap does not show whether the threshold decisions change.

Methods

Here, label-change impact assessment (LCIA) is proposed, from the label update to the audit at a clinical site. Level 1 compares the two label sets. Level 2 evaluates a model trained on the original labels against both. In Level 3, the model is retrained on each label set with the same initial state, batches and dropout, so that any RVEF shift is caused by the labels. The RVEF range for the two label sets flags each decision, which depends on the labels. LCIA is evaluated with 5 models on the 150 patients (50 for testing) of the Automated Cardiac Diagnosis Challenge (ACDC), and the nnU-Net is also tested on 320 external patients.

Results

The two label sets overlap almost completely (median Dice similarity coefficient 0.976), but the category at the 45 % threshold changes for 18 of the 150 patients. A model trained on the original labels misclassifies 13 of 50 test patients against the refined labels (4 against its own), and its overlap decreases only from 0.92 to 0.90. In four architectures, retraining moves the RVEF by a median of 3.4 to 4.7 percentage points, against 1.9 to 3.4 points between training runs. In a site audit, 11 of the 50 test decisions are flagged.

Conclusions

A label refinement that is not visible in the overlap can reclassify patients at clinical thresholds without any warning. LCIA detects these patients before a model is updated, and in an audit, it refers them to the clinician.

Zitieren

APA

Gionanidis, E., Tzallas, A. T., Giannakeas, N., & Miltiadous, A. (2026). When Reference Labels Change: A Framework for Assessing Deep Learning Measurement of Right Ventricular Ejection Fraction. Diagnostics, 16(23), 3934. https://doi.org/10.3390/diagnostics16233934

Vancouver

Gionanidis E, Tzallas AT, Giannakeas N, Miltiadous A. When Reference Labels Change: A Framework for Assessing Deep Learning Measurement of Right Ventricular Ejection Fraction. Diagnostics. 2026;16(23):3934. doi:10.3390/diagnostics16233934

BibTeX
@article{Gionanidis2026,
  author = {Gionanidis, Emmanouil and Tzallas, Alexandros T. and Giannakeas, Nikolaos and Miltiadous, Andreas},
  title = {When Reference Labels Change: A Framework for Assessing Deep Learning Measurement of Right Ventricular Ejection Fraction},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {23},
  pages = {3934},
  doi = {10.3390/diagnostics16233934}
}