Benchmarking Deep Learning Protocols in Dermoscopic Skin-Cancer Classification: Performance Sensitivity and the Limits of Grad-CAM in Auditing Data Leakage
Diagnostics · 21.11.2026 · 16 (23) · 3912
DOI: 10.3390/diagnostics16233912 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 21.11.2026. Verfasst von Su-Ying Wen und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Taipei City Hospital.
Abstract (Originalsprache)
Background/Objectives: Published HAM10000 results are hard to compare because evaluation choices, notably the data split, are rarely controlled. We establish a leakage-controlled benchmark for malignant-versus-benign dermoscopic classification, quantify how far evaluation choices move performance relative to architecture, and test whether attribution maps can reveal leakage.
Methods
Six ImageNet-pretrained convolutional neural networks and their ensembles were trained on HAM10000 (10,015 images) with a lesion-grouped split, three seeds, and validation-selected checkpoints and thresholds. The pipeline was repeated on an image-level split, ConvNeXt-Tiny was tested unchanged on ISIC 2020 (33,126 images), and eleven attribution methods were scored for faithfulness, localization and sensitivity to weight randomization.
Results
ConvNeXt-Tiny reached an area under the receiver operating characteristic curve (AUC) of 0.925 ± 0.005 (sensitivity 85.3%, specificity 83.0%), and an eight-model ensemble 0.940 ± 0.001 with a precision-recall AUC of 0.832, above the only published lesion-grouped comparator (0.822), whose AUC it matches within one standard error. The four modern architectures were indistinguishable (all pairwise p ≥ 0.43), whereas an image-level split raised AUC by 0.027 and last-epoch evaluation lowered it by 0.018. On ISIC 2020, where only melanoma is labeled positive, AUC was 0.730 and sensitivity at the transferred threshold fell from 84.6% (76.5% for melanoma) to 42.5%. Attribution methods agreed weakly (mean rank correlation 0.16), faithfulness was unrelated to localization, and none exposed the leakage-trained model; a union of the three most faithful maps improved faithfulness (p = 0.003).
Conclusions
Under leakage-controlled evaluation, an eight-model ensemble matches the best published result, but evaluation protocol moves performance more than architecture does and must always be reported. Explanation methods should be chosen by measured faithfulness and reported as a panel.
Förderung
- Taipei City Hospital
Zitieren
APA
Wen, S., Lin, Y., & Lee, H. (2026). Benchmarking Deep Learning Protocols in Dermoscopic Skin-Cancer Classification: Performance Sensitivity and the Limits of Grad-CAM in Auditing Data Leakage. Diagnostics, 16(23), 3912. https://doi.org/10.3390/diagnostics16233912
Vancouver
Wen S, Lin Y, Lee H. Benchmarking Deep Learning Protocols in Dermoscopic Skin-Cancer Classification: Performance Sensitivity and the Limits of Grad-CAM in Auditing Data Leakage. Diagnostics. 2026;16(23):3912. doi:10.3390/diagnostics16233912
BibTeX
@article{Wen2026,
author = {Wen, Su-Ying and Lin, Yuan-Mao and Lee, Hsi-Chieh},
title = {Benchmarking Deep Learning Protocols in Dermoscopic Skin-Cancer Classification: Performance Sensitivity and the Limits of Grad-CAM in Auditing Data Leakage},
journal = {Diagnostics},
year = {2026},
volume = {16},
number = {23},
pages = {3912},
doi = {10.3390/diagnostics16233912}
}
EUVIMED