Quantifying [18F]FDG Uptake in the Liver, Spleen, Aorta, Bone Marrow, and Superior Vena Cava Using TotalSegmentator on [18F]PET/CT Imaging
Diagnostics · 20.11.2026 · 16 (22) · 3895
DOI: 10.3390/diagnostics16223895 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 20.11.2026. Verfasst von Tanja Fromberg Gorlen und 7 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Danish Rheumatism Association.
Abstract (Originalsprache)
Background/Objectives: The measurement of radiotracer uptake in specific organs has potential clinical implications. However, manual delineation is time-consuming. We aimed to evaluate the agreement between manual delineation and automatic segmentation by the artificial intelligence model TotalSegmentator for extraction of standard uptake values (SUVs) from [18F]FDG-PET/CT scans for the aorta, spleen, lumbar spine bone marrow, liver, and superior vena cava.
Methods
The aorta, spleen, lumbar spine bone marrow, liver, and superior vena cava were segmented manually by trained physicians and automatically by the TotalSegmentator version 2.4 software, and the correlations between SUV values obtained were assessed.
Results
We found good agreement between manually and automatically obtained SUVmean values for the aorta (manual/TotalSegmentator: 2.10/2.11), spleen (2.00/1.95), liver (2.53/2.37), lumbar spine bone marrow (1.88/1.85), and superior vena cava (2.02/1.88) with high correlation coefficients across all organs, ranging from 0.93 to 0.99 and high intraclass correlation coefficients (ICCs) of 0.81–0.99. Agreement for SUVmax showed greater variability across the organs which were assessed: agreement was good for the spleen (ICC 0.83) and lumbar spine bone marrow (ICC 0.86), but weak for the aorta (ICC 0.11). Bland–Altman analyses for SUVmean indicated no systematic bias in the aorta or spleen, slight bias in bone marrow, liver, and superior vena cava, and variable bias for SUVmax across all structures.
Conclusions
TotalSegmentator provided reliable SUVmean values from the aorta, spleen, lumbar spine bone marrow, liver, and superior vena cava. However, the agreement between manually and automatically obtained SUVmax values was variable, suggesting that additional quality control steps should be applied if using TotalSegmentator for SUVmax extraction.
Förderung
- Danish Rheumatism Association
Zitieren
APA
Gorlen, T. F., Brittain, J. M., Smajlovic, E., Andersen, F. L., Østergaard, M., Hansen, P. R., Ripa, R. S., & Terslev, L. (2026). Quantifying [18F]FDG Uptake in the Liver, Spleen, Aorta, Bone Marrow, and Superior Vena Cava Using TotalSegmentator on [18F]PET/CT Imaging. Diagnostics, 16(22), 3895. https://doi.org/10.3390/diagnostics16223895
Vancouver
Gorlen TF, Brittain JM, Smajlovic E, Andersen FL, Østergaard M, Hansen PR, et al. Quantifying [18F]FDG Uptake in the Liver, Spleen, Aorta, Bone Marrow, and Superior Vena Cava Using TotalSegmentator on [18F]PET/CT Imaging. Diagnostics. 2026;16(22):3895. doi:10.3390/diagnostics16223895
BibTeX
@article{Gorlen2026,
author = {Gorlen, Tanja Fromberg and Brittain, Jane Maestri and Smajlovic, Edvin and Andersen, Flemming Littrup and Østergaard, Mikkel and Hansen, Peter Riis and Ripa, Rasmus Sejersten and Terslev, Lene},
title = {Quantifying [18F]FDG Uptake in the Liver, Spleen, Aorta, Bone Marrow, and Superior Vena Cava Using TotalSegmentator on [18F]PET/CT Imaging},
journal = {Diagnostics},
year = {2026},
volume = {16},
number = {22},
pages = {3895},
doi = {10.3390/diagnostics16223895}
}
EUVIMED