EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

NeuroEdge-X: Explainable Multi-Expert Fusion of Wearable Inertial Motion and Non-Motor Symptoms for Parkinson’s Disease Detection and Differential Diagnosis

Imran Khan, Haseeb Ur Rahman, Muhammad Ismail Mohmand, Khalil Ullah, Gulzar Mehmood, Mohammad Faisal

Diagnostics · 15.11.2026 · 16 (22) · 3797

DOI: 10.3390/diagnostics16223797 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 15.11.2026. Verfasst von Imran Khan und 5 weiteren Autor:innen. Die Arbeit nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Atlas University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Wearable models for Parkinson’s disease (PD) often use a single modality, overfit small cohorts, require complete inputs, give unfaithful explanations or suffer from subject leakage. We aimed to develop NeuroEdge-X, an explainable multi-expert model that fuses bilateral smartwatch motion from 11 standardized tasks with the 30-item non-motor symptom questionnaire of the same individuals.

Methods

A questionnaire expert, an interpretable spectral tremor expert and a MiniRocket random-convolution motion expert are combined by a stacked meta-learner, with a motion-only meta-learner when the questionnaire is missing. The model was evaluated on 469 participants of the PhysioNet PADS dataset under repeated subject-independent cross-validation, and the motion expert was also tested on an external gait cohort recorded with foot-pressure sensors.

Results

NeuroEdge-X reached 91.0% balanced accuracy (BA) and 97.0% AUROC for PD versus healthy controls and 75.0% BA and 82.7% AUROC for PD versus other movement disorders. Its gain over a fused logistic regression was small and not consistently significant; its practical advantages are that it retained 81.8% and 68.7% BA without the questionnaire and that its explanations are exact. The motion expert alone transferred to the external gait cohort (AUROC 83.5%). The explanations highlight tremor frequency, tremor regularity and action tasks; calibration, decision-curve and triage analyses support clinical interpretation. Profiled with PyTorch, ONNX Runtime and scikit-learn on one thread of a general-purpose CPU, the model processed a participant in 48 ms with 2.3 MB of working memory.

Conclusions

Because the questionnaire was completed after diagnosis, these estimates may be optimistic for undiagnosed people. The complete framework has not been validated externally, and edge deployment was not verified on an ultra-low-power wearable microcontroller.

Förderung

  • Atlas University

Zitieren

APA

Khan, I., Rahman, H. U., Mohmand, M. I., Ullah, K., Mehmood, G., & Faisal, M. (2026). NeuroEdge-X: Explainable Multi-Expert Fusion of Wearable Inertial Motion and Non-Motor Symptoms for Parkinson’s Disease Detection and Differential Diagnosis. Diagnostics, 16(22), 3797. https://doi.org/10.3390/diagnostics16223797

Vancouver

Khan I, Rahman HU, Mohmand MI, Ullah K, Mehmood G, Faisal M. NeuroEdge-X: Explainable Multi-Expert Fusion of Wearable Inertial Motion and Non-Motor Symptoms for Parkinson’s Disease Detection and Differential Diagnosis. Diagnostics. 2026;16(22):3797. doi:10.3390/diagnostics16223797

BibTeX
@article{Khan2026,
  author = {Khan, Imran and Rahman, Haseeb Ur and Mohmand, Muhammad Ismail and Ullah, Khalil and Mehmood, Gulzar and Faisal, Mohammad},
  title = {NeuroEdge-X: Explainable Multi-Expert Fusion of Wearable Inertial Motion and Non-Motor Symptoms for Parkinson’s Disease Detection and Differential Diagnosis},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {22},
  pages = {3797},
  doi = {10.3390/diagnostics16223797}
}