Diagnostic Performance of Angiography-Derived MPFFR for Predicting Hemodynamically Significant Coronary Stenosis: A Multicenter Validation Study
Diagnostics · 14.11.2026 · 16 (22) · 3777
DOI: 10.3390/diagnostics16223777 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 14.11.2026. Verfasst von Houng-Beom Ahn und 14 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Medical Device Development Fund.
Abstract (Originalsprache)
Background and Objectives: Angiography-derived fractional flow reserve (FFR) methods offer noninvasive alternatives to wire-based FFR for functional assessment of coronary stenosis, but their diagnostic performance requires validation. This study evaluated the diagnostic performance of artificial intelligence (AI)-driven angiography-based FFR for detecting hemodynamically significant coronary stenosis, as compared with percentage diameter stenosis (%DS) from quantitative coronary angiography (QCA), using invasive FFR as the reference standard.
Methods
In this prospective, multicenter study, 189 patients (211 lesions) undergoing clinically indicated angiography were enrolled. AI-driven angiography-based FFR and %DS were derived from angiographic images and compared with invasive FFR (cutoff ≤ 0.80). Diagnostic performance was assessed using AUROC, sensitivity, specificity, and predictive values, along with correlation analysis and analysis time.
Results
AI-driven angiography-based FFR showed significantly greater diagnostic performance than %DS (per-patient AUROC: 0.87 vs. 0.63, p < 0.001; per-lesion AUROC: 0.89 vs. 0.65, p < 0.001). AI-driven angiography-based FFR demonstrated higher specificity (92.7%) and positive predictive value (86.7%) than %DS (64.2% and 51.9%, respectively). AI-driven angiography-based FFR correlated strongly with invasive FFR (r = 0.746), whereas %DS showed a weak inverse correlation (r = −0.250). Median analysis time for AI-driven angiography-based FFR was 20.9 s. A gray-zone hybrid strategy (thresholds 0.73–0.83) yielded 89.8% accuracy and could reduce invasive FFR use by 57.1%.
Conclusions
AI-driven angiography-based FFR demonstrated high diagnostic accuracy, strong correlation with invasive FFR, and rapid analysis time. These findings support AI-driven angiography-based FFR as a pressure-wire-free tool for physiological assessment during coronary angiography.
Förderung
- Korea Medical Device Development Fund
Zitieren
APA
Ahn, H., Kwun, J., Jeon, K., Lee, W., Yoon, C., Chu, H., Seo, W., Han, D., Park, S., Doh, J. H., Nam, C., Shin, E., Koo, B., Chae, I., & Youn, T. (2026). Diagnostic Performance of Angiography-Derived MPFFR for Predicting Hemodynamically Significant Coronary Stenosis: A Multicenter Validation Study. Diagnostics, 16(22), 3777. https://doi.org/10.3390/diagnostics16223777
Vancouver
Ahn H, Kwun J, Jeon K, Lee W, Yoon C, Chu H, et al. Diagnostic Performance of Angiography-Derived MPFFR for Predicting Hemodynamically Significant Coronary Stenosis: A Multicenter Validation Study. Diagnostics. 2026;16(22):3777. doi:10.3390/diagnostics16223777
BibTeX
@article{Ahn2026,
author = {Ahn, Houng-Beom and Kwun, Ju-Seung and Jeon, Ki-Hyun and Lee, Wonjae and Yoon, Chang-Hwan and Chu, Hyun-Wook and Seo, Won-Woo and Han, Donghoon and Park, Sang-Don and Doh, Joon Hyung and Nam, Chang-Wook and Shin, Eun-Seok and Koo, Bon-Kwon and Chae, In-Ho and Youn, Tae-Jin},
title = {Diagnostic Performance of Angiography-Derived MPFFR for Predicting Hemodynamically Significant Coronary Stenosis: A Multicenter Validation Study},
journal = {Diagnostics},
year = {2026},
volume = {16},
number = {22},
pages = {3777},
doi = {10.3390/diagnostics16223777}
}
EUVIMED