Abstract (Originalsprache)

Background

Optical coherence tomography (OCT) retinal layer segmentation supports quantitative clinical assessment, but its robustness to different image degradation has not been systematically characterized.

Methods

This study evaluates a U-Net trained on unmodified OCT5k scans under seven synthetic degradation families at five family-specific severity levels. The test set included 315 held-out B-scans from nine cases, with three cases each of age-related macular degeneration, diabetic macular edema, and healthy retinas. After ordered boundary decoding, two primary outcomes were calculated: boundary mean absolute error (MAE, pixels) and internal-layer Dice.

Results

Clean images yielded macro-MAE of 3.66 pixels and macro-Dice of 0.934. At severity 5, MAE increased in five families and Dice decreased in all seven. Gaussian noise, contrast reduction, and global attenuation produced the largest deterioration, with macro-MAE/macro-Dice values of 94.35/0.715, 236.81/0.044, and 112.32/0.0004, respectively. Adjusted paired tests showed statistically significant deterioration in both outcomes for these three families; macro-Dice also showed declines under defocus, shadowing, and axial-resolution reduction, while speckle showed no significant change.

Conclusions

These results indicate corruption- and metric-specific vulnerability in the tested U-Net. This study may inform the development of automated OCT image-quality screening. Before clinical use, these findings may be evaluated on other segmentation models, larger datasets, additional OCT devices, and with naturally occurring acquisition artifacts.

Förderung

  • King Faisal University

Zitieren

APA

Gardner, M. R. (2026). Robustness of U-Net Retinal Layer Segmentation to Controlled OCT Image Degradation. Diagnostics, 16(22), 3754. https://doi.org/10.3390/diagnostics16223754

Vancouver

Gardner MR. Robustness of U-Net Retinal Layer Segmentation to Controlled OCT Image Degradation. Diagnostics. 2026;16(22):3754. doi:10.3390/diagnostics16223754

BibTeX
@article{Gardner2026,
  author = {Gardner, Michael R.},
  title = {Robustness of U-Net Retinal Layer Segmentation to Controlled OCT Image Degradation},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {22},
  pages = {3754},
  doi = {10.3390/diagnostics16223754}
}
Kostenlos starten →