Ultrasonographic Evaluation of Masseter Muscle Thickness and Fractal Dimension in Bruxist and Healthy Individuals
Diagnostics · 04.11.2026 · 16 (21) · 3648
DOI: 10.3390/diagnostics16213648 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 04.11.2026. Verfasst von Esin Akol Görgün und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Adıyaman University, Altınşehir Mah. 3005 Sok. No: 13, 02040 Adıyaman, Türkiye. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: This study aimed to determine whether masseter muscle thickness and ultrasound-derived fractal dimension (FD) differ between patients with bruxism and healthy controls.
Methods
Thirty patients with clinically assessed bruxism and 30 healthy volunteers (15 female, 15 male each) were included. Bruxism required a history of tooth grinding or clenching for at least one year plus at least one of three additional findings (tooth wear, masseter tenderness on palpation, morning jaw pain or headache); controls had none of these findings. Bilateral B-mode scans were acquired at rest and during maximum clenching under standardized settings. Thickness was measured with calipers, and FD was calculated by box-counting in ImageJ (version 1.54f) from three 100 × 100-pixel regions of interest per image. Intraobserver reliability was excellent for thickness (ICC = 0.967–0.980) and good for FD (ICC = 0.850–0.929).
Results
Thickness was greater in bruxism patients on both sides and in both conditions (p < 0.001; bilateral mean at rest 12.95 ± 1.47 vs. 9.72 ± 1.78 mm). Bilateral mean FD was higher in bruxism patients during clenching (1.202 ± 0.027 vs. 1.182 ± 0.028; p = 0.008), and this difference remained significant after Holm correction across six FD comparisons. The resting difference (1.188 ± 0.026 vs. 1.171 ± 0.031; p = 0.029) was not robust to multiplicity correction or to exclusion of two controls whose regions of interest extended beyond the muscle.
Conclusions
Clinically assessed bruxism was associated with greater masseter thickness in this sample. Bilateral mean FD was modestly higher during clenching; the resting FD difference was not robust. The reproducibility and clinical relevance of these texture measures require further study.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Adıyaman University, Altınşehir Mah. 3005 Sok. No: 13, 02040 Adıyaman, Türkiye.
ORCID-Profile: Esin Akol Görgün, Ayşegül Öndeş
Zitieren
APA
Akol Görgün, E., & Öndeş, A. (2026). Ultrasonographic Evaluation of Masseter Muscle Thickness and Fractal Dimension in Bruxist and Healthy Individuals. Diagnostics, 16(21), 3648. https://doi.org/10.3390/diagnostics16213648
Vancouver
Akol Görgün E, Öndeş A. Ultrasonographic Evaluation of Masseter Muscle Thickness and Fractal Dimension in Bruxist and Healthy Individuals. Diagnostics. 2026;16(21):3648. doi:10.3390/diagnostics16213648
BibTeX
@article{AkolGrgn2026,
author = {Akol Görgün, Esin and Öndeş, Ayşegül},
title = {Ultrasonographic Evaluation of Masseter Muscle Thickness and Fractal Dimension in Bruxist and Healthy Individuals},
journal = {Diagnostics},
year = {2026},
volume = {16},
number = {21},
pages = {3648},
doi = {10.3390/diagnostics16213648}
}
EUVIMED