Automatic Detection of Dental Implant Brands and Exposure Status Using Deep Learning on Periapical Radiographs
Diagnostics · 04.11.2026 · 16 (21) · 3644
DOI: 10.3390/diagnostics16213644 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 04.11.2026. Verfasst von Chih-Hao Chang und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computer Science and Information Engineering, National Central University, Taoyuan City 320317, Taiwan. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council, National Science and Technology Council (NSTC), Taiwan.
Abstract (Originalsprache)
Background/Objectives: Dental implant technology has become the primary treatment modality for managing tooth loss in current clinical practice. Accurate identification of implant brands and their clinical exposure status have increasingly emerged as a critical issue in implant-related research and clinical diagnosis. Conventional approaches that rely on clinicians’ experience are time-consuming and may lead to misclassification due to variations in image quality or subtle differences in implant design features across brands.
Methods
This single-center study classified six categories combining two implant brands (3i and Xive) and three exposure statuses. A retrospective cohort of 497 patients (708 periapical radiographs, 928 implant instances) was partitioned using an 8:1:1 stratified ratio with strict patient-level independence. Following YOLOv8-based implant localization and ROI extraction, classification was evaluated across deep learning backbones using 5-fold cross-validation and compared against a panel of three dental specialists on a test set of 8 complex cases.
Results
YOLOv8 achieved a precision of 99.39% and a sensitivity of 98.63% in the implant detection task. For the classification of implant brand and exposure status, EfficientNet-B3 achieved the best performance with an accuracy of 99.18 ± 0.85% (95% CI: [94.20%, 100.00%]) across 5-fold cross-validation, demonstrating competitive diagnostic performance alongside existing implant classification benchmarks in the literature. In a preliminary clinical feasibility assessment on representative cases, the framework demonstrated rapid algorithmic inference (mean inference time of 36.18 ms per image), providing instant decision-support potential alongside participating clinicians.
Conclusions
This study demonstrates the technical feasibility and proof-of-concept of a deep learning framework for identifying dental implant brands and exposure status under robust internal validation. While offering preliminary decision-support potential, external validation on multi-center cohorts and prospective clinical trials across expanded implant systems remain necessary before clinical implementation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Computer Science and Information Engineering, National Central University, Taoyuan City 320317, Taiwan.
- Department of Operative Dentistry, Taoyuan Chang Gung Memorial Hospital, Taoyuan City 333008, Taiwan.
- Department of Electronic Engineering, Chung Yuan Christian University, Taoyuan City 320314, Taiwan.
- Department of Information Management, Chung Yuan Christian University, Taoyuan City 320314, Taiwan.
- Program on Semiconductor Manufacturing Technology, Academy of Innovative Semiconductor and Sustainable Manufacturing, National Cheng Kung University, Tainan City 701401, Taiwan.
- Research Center for Semiconductor Materials and Advanced Optics, Chung Yuan Christian University, Taoyuan City 320314, Taiwan.
ORCID-Profile: Chih-Hao Chang, Kuo-Chen Li, Yuan-Jin Lin, Shih-Lun Chen, Tsung-Yi Chen, Patricia Angela R Abu, Wei-Chen Tu
Förderung
- National Science and Technology Council
- National Science and Technology Council (NSTC), Taiwan
Zitieren
APA
Chang, C. H., Mao, Y. C., Sung, C. Y., Su, H. K., Li, K. C., Lin, Y. J., Chen, S. L., Hsu, D. W., Chen, T. Y., Abu, P. A. R., Tu, W. C., & Wang, J. C. (2026). Automatic Detection of Dental Implant Brands and Exposure Status Using Deep Learning on Periapical Radiographs. Diagnostics, 16(21), 3644. https://doi.org/10.3390/diagnostics16213644
Vancouver
Chang CH, Mao YC, Sung CY, Su HK, Li KC, Lin YJ, et al. Automatic Detection of Dental Implant Brands and Exposure Status Using Deep Learning on Periapical Radiographs. Diagnostics. 2026;16(21):3644. doi:10.3390/diagnostics16213644
BibTeX
@article{Chang2026,
author = {Chang, Chih-Hao and Mao, Yi-Cheng and Sung, Chien-Yu and Su, Hsin-Kai and Li, Kuo-Chen and Lin, Yuan-Jin and Chen, Shih-Lun and Hsu, Da-Wei and Chen, Tsung-Yi and Abu, Patricia Angela R and Tu, Wei-Chen and Wang, Jia-Ching},
title = {Automatic Detection of Dental Implant Brands and Exposure Status Using Deep Learning on Periapical Radiographs},
journal = {Diagnostics},
year = {2026},
volume = {16},
number = {21},
pages = {3644},
doi = {10.3390/diagnostics16213644}
}
EUVIMED