Transdiscal Versus Cement-Augmented Pedicle Screw Fixation for Thoracolumbar Fractures in Patients with Diffuse Idiopathic Skeletal Hyperostosis (DISH)
Diagnostics · 29.10.2026 · 16 (21) · 3576
DOI: 10.3390/diagnostics16213576 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 29.10.2026. Verfasst von Akiyoshi Miyamoto und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Okayama Rosai Hospital, 1-10-25 Chikkō Midorimachi, Minami Ward, Okayama 702-8055, Japan. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: Rigid internal fixation and early mobilization using pedicle screws have become a standard treatment option for vertebral fractures in patients with diffuse idiopathic skeletal hyperostosis. Poor bone quality and a long lever arm may result in a high rate of screw loosening, screw pullout, and implant failure in these patients. Therefore, researchers have developed various techniques to enhance fixation strength, including cement-augmented fenestrated pedicle screw (CAFPS) and transdiscal screw (TDS) fixation. This study compared the clinical and radiological outcomes of CAFPS and TDS fixation techniques for treating diffuse idiopathic skeletal hyperostosis (DISH)-associated thoracolumbar vertebral fractures. This study compared the clinical and radiological outcomes of CAFPS and TDS fixation techniques for DISH-associated thoracolumbar vertebral fractures.
Methods
Retrospective comparative cohort study. An evaluation was conducted of patients who underwent posterior instrumentation for vertebral fractures accompanied by DISH, using CAFPS or TDS techniques, at our hospital between August 2019 and March 2025. We assessed preoperative, operative, and postoperative data, outcomes, and radiographic parameters.
Results
We included 40 patients; 11 received CAFPS, and 29 received TDS fixation. Operative time (104 ± 19.6 min vs. 115 ± 29.4 min, p = 0.32), blood loss (87.7 ± 69.4 mL vs. 88.3 ± 64.8 mL, p = 0.95), and bone union rate (100% vs. 89.7%, p = 0.27) did not differ significantly. The incidence of screw loosening number was higher in the TDS group (5.68% vs. 13.4%, p = 0.049). However, patient-level analysis showed no difference (4/11 vs. 7/29, p = 0.455). Neither group had implant backouts, failures, or reoperations.
Conclusions
Transdiscal screws and transdiscal and cement-augmented pedicle screws are useful techniques for treating thoracolumbar vertebral fractures in patients with DISH. These techniques can reduce the level of fixation in vulnerable patient populations.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Okayama Rosai Hospital, 1-10-25 Chikkō Midorimachi, Minami Ward, Okayama 702-8055, Japan.
- Department of Orthopaedic Surgery, International University of Health and Welfare, Narita Hospital, Chiba 286-8520, Japan.
- Department of Orthopaedic and Traumatology Clinic, Memorial Bahçeliever Hospital, Istanbul 34180, Turkey.
- Department of Radiology, Okayama Rosai Hospital, 1-10-25 Chikkō Midorimachi, Minami Ward, Okayama 702-8055, Japan.
ORCID-Profile: Masato Tanaka, Ahmed Majid Heydar, Mitsuru Yagi, Haruki Funao
Zitieren
APA
Miyamoto, A., Tanaka, M., Heydar, A. M., Komatsubara, T., Ugawa, R., Nagamatsu, M., Yagi, M., Funao, H., & Isogai, N. (2026). Transdiscal Versus Cement-Augmented Pedicle Screw Fixation for Thoracolumbar Fractures in Patients with Diffuse Idiopathic Skeletal Hyperostosis (DISH). Diagnostics, 16(21), 3576. https://doi.org/10.3390/diagnostics16213576
Vancouver
Miyamoto A, Tanaka M, Heydar AM, Komatsubara T, Ugawa R, Nagamatsu M, et al. Transdiscal Versus Cement-Augmented Pedicle Screw Fixation for Thoracolumbar Fractures in Patients with Diffuse Idiopathic Skeletal Hyperostosis (DISH). Diagnostics. 2026;16(21):3576. doi:10.3390/diagnostics16213576
BibTeX
@article{Miyamoto2026,
author = {Miyamoto, Akiyoshi and Tanaka, Masato and Heydar, Ahmed Majid and Komatsubara, Tadashi and Ugawa, Ryo and Nagamatsu, Masakazu and Yagi, Mitsuru and Funao, Haruki and Isogai, Norihiro},
title = {Transdiscal Versus Cement-Augmented Pedicle Screw Fixation for Thoracolumbar Fractures in Patients with Diffuse Idiopathic Skeletal Hyperostosis (DISH)},
journal = {Diagnostics},
year = {2026},
volume = {16},
number = {21},
pages = {3576},
doi = {10.3390/diagnostics16213576}
}
EUVIMED