Bei hospitalisierten COPD-Exazerbationen sank FeNO unter Behandlung von der Aufnahme bis zur Entlassung. FeNO und Blut-Eosinophile stimmten nur schlecht überein und sagten die Verweildauer nicht voraus.

Fragestellung

Beschreibt die Studie den Verlauf von FeNO bei behandelten COPD-Exazerbationen und die Übereinstimmung mit Blut-Eosinophilen sowie die Vorhersage der Verweildauer?

Methode

Prospektive Kohortenstudie bei hospitalisierten Patient:innen mit AECOPD. FeNO, Blut-Eosinophile, Spirometrie und Blutgase wurden zu festgelegten Zeitpunkten unter leitliniengerechter Therapie erhoben.

Ergebnisse

FeNO sank von 16 (IQR 10–25) ppb auf 13,5 (7–20) ppb an Tag 2 und 9 (6–18) ppb bei Entlassung (p < 0,001). Blut-Eosinophile fielen von 60 (20–150) auf 0 (0–40) Zellen/µL; κ 0,08 (95 %-KI −0,15 bis +0,30).

Schlussfolgerung der Autor:innen

FeNO nimmt unter Behandlung einer AECOPD ab; die bei Aufnahme vergebene Typ-2-Kennzeichnung war nach 48 h für die meisten Patient:innen nicht mehr gültig. FeNO und Blut-Eosinophile identifizierten weitgehend unterschiedliche Patient:innen, und kein Biomarker sagte die Verweildauer voraus.

Kernaussagen

  • FeNO sank bis zur Entlassung deutlich ab.
  • Übereinstimmung mit Blut-Eosinophilen war schlecht.
  • Kein Biomarker sagte die Verweildauer voraus.

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 29.10.2026. Verfasst von Dimitrios Potonos und 6 weiteren Autor:innen. Beteiligte Einrichtung: Respiratory Medicine Department, University of Ioannina, 45110 Ioannina, Greece. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The behavior of fractional exhaled nitric oxide (FeNO) during treated COPD exacerbations and its agreement with blood eosinophil counts are poorly characterized.

Objectives

To describe serial FeNO trajectories across hospitalized COPD exacerbations (AECOPDs), assess concordance between FeNO and blood eosinophils, and test whether these can predict length of stay (LOS).

Methods

Prospective cohort of patients hospitalized for AECOPD. FeNO was measured on admission, on day 2 and at discharge; blood eosinophils and post-bronchodilator spirometry on admission and before discharge; and arterial blood gases on admission and on day 2. The admission measurements preceded the first dose of corticosteroid. All patients received guideline-directed treatment, including systemic corticosteroids.

Results

Most patients were male (94.7%), with a mean age of 71.7 ± 8.3 years. FeNO fell from 16 (IQR 10–25) ppb on admission to 13.5 (7–20) ppb on day 2 and 9 (6–18) ppb at discharge (p < 0.001). Blood eosinophils fell from 60 (20–150) to 0 (0–40) cells/µL (p < 0.001), and FEV1 increased from 38% to 45% predicted (p < 0.001). Agreement between biomarkers on admission was poor (ρ = 0.21, p = 0.07; κ = 0.08, 95% CI −0.15 to +0.30), and 31 patients (40.8%) were classified differently by the two markers. Admission FeNO (ρ = 0.03, p = 0.79), ΔFeNO (ρ = −0.12, p = 0.31), and admission eosinophils (ρ = −0.08, p = 0.49) were not associated with LOS. Of the patients who were type-2-high on admission (FeNO ≥ 20 ppb), 57% had fallen below that threshold by day 2 and 62% by discharge (71% and 71%, respectively, at ≥25 ppb). Over the admission-to-discharge interval, the changes in the two markers were unrelated once each was adjusted for its own admission value (partial ρ = 0.05, p = 0.73), and there was no agreement on the direction of change (κ = 0.03).

Conclusions

FeNO progressively declines during treated AECOPD, alongside a fall in the blood eosinophil count, so that the type-2 label assigned on admission is no longer valid for most patients 48 h later. FeNO and blood eosinophils identified largely non-overlapping patients, and no biomarker predicted length of stay.

Schlagwörter

Stichwörter der Autor:innen

COPDblood eosinophilsexacerbationfractional exhaled nitric oxidetreatable traitstype-2 inflammation

Autor:innen und Institutionen

  • Respiratory Medicine Department, University of Ioannina, 45110 Ioannina, Greece.

ORCID-Profile: Dimitrios Potonos, Antonia Assioura, Athena Gogali, Emmanouil D Oikonomou, Konstantinos Exarchos, Christos Kyriakopoulos, Konstantinos Kostikas

Zitieren

APA

Potonos, D., Assioura, A., Gogali, A., Oikonomou, E. D., Exarchos, K., Kyriakopoulos, C., & Kostikas, K. (2026). Fractional Exhaled Nitric Oxide Falls Progressively During Treated Exacerbations of COPD and Is Discordant with Blood Eosinophil Counts. Diagnostics, 16(21), 3567. https://doi.org/10.3390/diagnostics16213567

Vancouver

Potonos D, Assioura A, Gogali A, Oikonomou ED, Exarchos K, Kyriakopoulos C, et al. Fractional Exhaled Nitric Oxide Falls Progressively During Treated Exacerbations of COPD and Is Discordant with Blood Eosinophil Counts. Diagnostics. 2026;16(21):3567. doi:10.3390/diagnostics16213567

BibTeX
@article{Potonos2026,
  author = {Potonos, Dimitrios and Assioura, Antonia and Gogali, Athena and Oikonomou, Emmanouil D and Exarchos, Konstantinos and Kyriakopoulos, Christos and Kostikas, Konstantinos},
  title = {Fractional Exhaled Nitric Oxide Falls Progressively During Treated Exacerbations of COPD and Is Discordant with Blood Eosinophil Counts},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {21},
  pages = {3567},
  doi = {10.3390/diagnostics16213567}
}
Kostenlos starten →