Evaluation of the Diagnostic Accuracy of Different Imaging Modalities in Patients with Pathologic Nipple Discharge

Riku Togawa, Dina Batarseh iD, Helena Dahm, Thomas M Deutsch, André Hennigs, Andrea Lemke, André Pfob, Walid Shaalan iD, Anne Stieber, Oliver Zivanovic, Jörg Heil iD, Michael Golatta iD und 1 weitere

Diagnostics · 27.10.2026 · 16 (21) · 3530

DOI: 10.3390/diagnostics16213530 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 27.10.2026. Verfasst von Riku Togawa und 12 weiteren Autor:innen. Beteiligte Einrichtung: Breast Unit, Department of Obstetrics and Gynecology, Heidelberg University Hospital, Im Neuenheimer Feld 440, 69120 Heidelberg, Germany. Die Arbeit nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: To evaluate the diagnostic accuracy of different imaging modalities in patients with pathologic nipple discharge.

Methods

This is a single-centre retrospective analysis of patients with pathologic nipple discharge. All performed imaging modalities were reviewed for their sensitivity and specificity in correctly diagnosing malignancy, as well as lesions with uncertain malignant potential (B3).

Results

Of 388 patients, pathology or follow-up confirmed 41 cases of malignancy (15 breast cancer, 26 ductal carcinoma in situ (DCIS)), 151 cases of B3 lesions, and 196 benign cases. The combination of ultrasound and mammography/tomosynthesis achieved a sensitivity of 82.5% (95% CI 68.1–91.3) and a specificity of 83.5% (77.4–88.2) for the detection of malignancy. For the classification of B3 lesions as suspicious (BI-RADS 4/5), the sensitivity and specificity were 33.8% (26.7–41.7) and 83.5% (77.4–88.2), respectively. Ductography demonstrated a sensitivity of 89.3% (72.8–96.3) and a specificity of 13.3% (8.2–20.8) for malignancy, while MRI showed a sensitivity of 71.4% (45.4–88.3) and a specificity of 90.0% (76.9–96.0). In classifying B3 lesions as suspicious, ductography reached a sensitivity of 94.8% (89.7–97.5) and a specificity of 13.3% (8.2–20.8), compared to 75.9% (57.9–87.8) and 90.0% (76.9–96.0), respectively, for MRI.

Conclusions

While the combination of ultrasound and mammography/tomosynthesis correctly classified 82.5% of breast malignancies associated with pathologic nipple discharge as suspicious, their sensitivity for classifying B3 lesions as suspicious was only moderate (33.8%). In patients with negative or inconclusive conventional imaging but persistent clinical suspicion, MRI may be considered as an additional diagnostic tool, whereas ductography, given its low specificity, is of limited value for assessing lesion dignity and may primarily serve to localize the affected duct prior to surgery. Further research is needed to determine which diagnostic modality provides the greatest benefit in specific cases.

Schlagwörter

Stichwörter der Autor:innen

MRIbreast cancerductographymammographypathologic nipple dischargeultrasound

Autor:innen und Institutionen

  • Breast Unit, Department of Obstetrics and Gynecology, Heidelberg University Hospital, Im Neuenheimer Feld 440, 69120 Heidelberg, Germany.
  • Breast Unit, Sankt Elisabeth Hospital, Max-Reger-Strasse 5-8, 69121 Heidelberg, Germany.
  • Department of Diagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 440, 69120 Heidelberg, Germany.

ORCID-Profile: Dina Batarseh, Walid Shaalan, Jörg Heil, Michael Golatta, Fabian Riedel

Zitieren

APA

Togawa, R., Batarseh, D., Dahm, H., Deutsch, T. M., Hennigs, A., Lemke, A., Pfob, A., Shaalan, W., Stieber, A., Zivanovic, O., Heil, J., Golatta, M., & Riedel, F. (2026). Evaluation of the Diagnostic Accuracy of Different Imaging Modalities in Patients with Pathologic Nipple Discharge. Diagnostics, 16(21), 3530. https://doi.org/10.3390/diagnostics16213530

Vancouver

Togawa R, Batarseh D, Dahm H, Deutsch TM, Hennigs A, Lemke A, et al. Evaluation of the Diagnostic Accuracy of Different Imaging Modalities in Patients with Pathologic Nipple Discharge. Diagnostics. 2026;16(21):3530. doi:10.3390/diagnostics16213530

BibTeX
@article{Togawa2026,
  author = {Togawa, Riku and Batarseh, Dina and Dahm, Helena and Deutsch, Thomas M and Hennigs, André and Lemke, Andrea and Pfob, André and Shaalan, Walid and Stieber, Anne and Zivanovic, Oliver and Heil, Jörg and Golatta, Michael and Riedel, Fabian},
  title = {Evaluation of the Diagnostic Accuracy of Different Imaging Modalities in Patients with Pathologic Nipple Discharge},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {21},
  pages = {3530},
  doi = {10.3390/diagnostics16213530}
}
Kostenlos starten →