Diagnostic Accuracy of Machine and Deep Learning Methods in Intracranial Hemorrhage Detection: A Systematic Review and Meta-Analysis

Anastasis Alexopoulos iD, Yiheng Tan iD, Maarten Uyttenboogaart, Mathias Prokop, Ronald J H Borra, Maarten M H Lahr, Reinoud P H Bokkers iD

Diagnostics · 27.10.2026 · 16 (21) · 3516

DOI: 10.3390/diagnostics16213516 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Diagnostics, online erschienen am 27.10.2026. Verfasst von Anastasis Alexopoulos und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University Medical Center Groningen, University of Groningen, 9700 AB Groningen, The Netherlands. Die Arbeit nennt 98 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Netherlands Organization for Health Research and Development, the Dutch Ministry of Economic Affairs and Climate Policy, Siemens Healthineers.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: In this systematic review we investigated the diagnostic accuracy of machine and deep learning algorithms for the detection of intracranial hemorrhage (ICH) and its subtypes such as subarachnoid, intraventricular, intraparenchymal, subdural and epidural hemorrhage. In addition, we investigated their generalizability by comparing methods tested on private vs. public datasets, and FDA- vs. non-FDA-approved algorithms.

Methods

PubMed, Scopus and Embase were searched between January 2010 and December 2025. Eligible studies included patients with acute neurological deficit that received non-contrast CT head scans and implemented machine and deep learning algorithms for ICH detection, that were tested on private and/or public datasets, received FDA approval or not, and used clinicians’ evaluation as reference standard. Pooled sensitivity and specificity were incorporated for meta-analysis.

Results

A total of 89 publications received full assessment and 51 studies were included in the meta-analysis. The pooled sensitivity and specificity for ICH detection were 94.5% (95% CI: 92.4–96.0) and 95.3% (95% CI: 93.1–96.9), respectively. For AI methods tested on private and public datasets, the pooled sensitivity reached 94.4% (95% CI: 91.2–96.5) and 94.5% (95% CI: 91.8–96.4), with a pooled specificity in 95.6% (95% CI: 92.9–97.2) and 95.1% (95% CI: 90.1–97.5), respectively. FDA- and non-FDA-approved AI algorithms showed a pooled sensitivity of 90.7% (95% CI: 87.1–93.4) and specificity of 95.8% (95% CI: 90.3–98.3) in the former group, and 95.5% (95% CI: 93.4–96.9) and 95.7% (95% CI: 92.4–97.6) for the latter group.

Conclusions

Study results demonstrated that the diagnostic accuracy of the developed AI algorithms for ICH detection is equivalent to that of experienced clinicians. Methods tested on private and public datasets, and FDA- vs. non-FDA-approved, differ slightly in ICH diagnosis, showing encouraging signs for their incorporation in decision support systems in stroke patient pathways.

Schlagwörter

Stichwörter der Autor:innen

deep learningintracranial hemorrhagemachine learningstroke

Autor:innen und Institutionen

  • Department of Radiology, University Medical Center Groningen, University of Groningen, 9700 AB Groningen, The Netherlands.
  • Department of Neurology, University Medical Center Groningen, University of Groningen, 9700 AB Groningen, The Netherlands.
  • Department of Imaging, Radboud University Medical Center, 6500 HB Nijmegen, The Netherlands.
  • Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, 9700 AB Groningen, The Netherlands.
  • Department of Epidemiology, University Medical Center Groningen, University of Groningen, 9700 AB Groningen, The Netherlands.

ORCID-Profile: Anastasis Alexopoulos, Yiheng Tan, Reinoud P H Bokkers

Förderung

  • The Netherlands Organization for Health Research and Development
  • the Dutch Ministry of Economic Affairs and Climate Policy
  • Siemens Healthineers

Zitieren

APA

Alexopoulos, A., Tan, Y., Uyttenboogaart, M., Prokop, M., Borra, R. J. H., Lahr, M. M. H., & Bokkers, R. P. H. (2026). Diagnostic Accuracy of Machine and Deep Learning Methods in Intracranial Hemorrhage Detection: A Systematic Review and Meta-Analysis. Diagnostics, 16(21), 3516. https://doi.org/10.3390/diagnostics16213516

Vancouver

Alexopoulos A, Tan Y, Uyttenboogaart M, Prokop M, Borra RJH, Lahr MMH, et al. Diagnostic Accuracy of Machine and Deep Learning Methods in Intracranial Hemorrhage Detection: A Systematic Review and Meta-Analysis. Diagnostics. 2026;16(21):3516. doi:10.3390/diagnostics16213516

BibTeX
@article{Alexopoulos2026,
  author = {Alexopoulos, Anastasis and Tan, Yiheng and Uyttenboogaart, Maarten and Prokop, Mathias and Borra, Ronald J H and Lahr, Maarten M H and Bokkers, Reinoud P H},
  title = {Diagnostic Accuracy of Machine and Deep Learning Methods in Intracranial Hemorrhage Detection: A Systematic Review and Meta-Analysis},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {21},
  pages = {3516},
  doi = {10.3390/diagnostics16213516}
}
Kostenlos starten →