EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Factors Associated with the Accuracy of Sonographic Fetal Weight Estimation: A Study of 1262 Vietnamese Pregnancies

Ngoc Diem Doan Phan iD, Quang Chi Nguyen, Trang Thi Thu Nguyen, Xuan Thi Huong Nguyen, Nhung Huynh Ho iD, Quang Sy Nguyen, Thuy Thi Chau, Duong Huu Quach, Tuyen Kim Cat Vo

Diagnostics · 23.10.2026 · 16 (21) · 3457

DOI: 10.3390/diagnostics16213457 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 23.10.2026. Verfasst von Ngoc Diem Doan Phan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Vinmec Central Park International Hospital, Vinmec International Hospital, Ho Chi Minh City 70000, Vietnam. Die Arbeit nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Sonographic estimated fetal weight (EFW) guides many obstetric decisions. We examined maternal, fetal and sonographic factors associated with EFW error using the Hadlock II, Hadlock III and Shinozuka formulas.

Methods

This is a retrospective cross-sectional study of 1262 singleton pregnancies at 30–41 weeks scanned within 3 days before delivery. Accuracy was assessed by mean percentage error (MPE), mean absolute percentage error (MAPE), successful estimation rate (SER; error ≤ 10%), Bland–Altman analysis with regression-based limits of agreement and Deming regression. Formulas were compared with paired tests. Each factor’s contribution was measured as the decrease in Nagelkerke R2 (ΔR2) in multivariable logistic regression; factor × formula interactions were tested with generalised estimating equations (GEE).

Results

MAPE was 5.44%, 5.64% and 5.75% and SER 86.2%, 84.2% and 84.5% for Hadlock II, Hadlock III and Shinozuka, respectively; differences between formulas were small (ΔMAPE ≤ 0.31 percentage points). Against birth weight, all three overestimated small and underestimated large fetuses (Deming slopes 0.79–0.85). Birth weight was the strongest correlate of SER (decrease in Nagelkerke R2, 0.052–0.129) and, in the main analysis, the only factor whose effect differed between formulas (p < 0.001); other factors reduced Nagelkerke R2 by

Schlagwörter

Stichwörter der Autor:innen

Hadlock formulaShinozuka formulaVietnamfetal biometryfetal weight estimationmacrosomiaobstetric ultrasound

Autor:innen und Institutionen

  • Department of Obstetrics and Gynecology, Vinmec Central Park International Hospital, Vinmec International Hospital, Ho Chi Minh City 70000, Vietnam.
  • College of Health Sciences, VinUniversity, Hanoi 10000, Vietnam.
  • School of Medicine, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City 70000, Vietnam.

ORCID-Profile: Ngoc Diem Doan Phan, Nhung Huynh Ho

Zitieren

APA

Phan, N. D. D., Nguyen, Q. C., Nguyen, T. T. T., Nguyen, X. T. H., Ho, N. H., Nguyen, Q. S., Chau, T. T., Quach, D. H., & Vo, T. K. C. (2026). Factors Associated with the Accuracy of Sonographic Fetal Weight Estimation: A Study of 1262 Vietnamese Pregnancies. Diagnostics, 16(21), 3457. https://doi.org/10.3390/diagnostics16213457

Vancouver

Phan NDD, Nguyen QC, Nguyen TTT, Nguyen XTH, Ho NH, Nguyen QS, et al. Factors Associated with the Accuracy of Sonographic Fetal Weight Estimation: A Study of 1262 Vietnamese Pregnancies. Diagnostics. 2026;16(21):3457. doi:10.3390/diagnostics16213457

BibTeX
@article{Phan2026,
  author = {Phan, Ngoc Diem Doan and Nguyen, Quang Chi and Nguyen, Trang Thi Thu and Nguyen, Xuan Thi Huong and Ho, Nhung Huynh and Nguyen, Quang Sy and Chau, Thuy Thi and Quach, Duong Huu and Vo, Tuyen Kim Cat},
  title = {Factors Associated with the Accuracy of Sonographic Fetal Weight Estimation: A Study of 1262 Vietnamese Pregnancies},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {21},
  pages = {3457},
  doi = {10.3390/diagnostics16213457}
}
Kostenlos starten →