Accuracy and Usability of Emergency Department Diagnostic Codes: A Multicentre Observational Study
Diagnostics · 07.09.2026 · 16 (17) · 2872
DOI: 10.3390/diagnostics16172872 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 07.09.2026. Verfasst von Viet Tran und 5 weiteren Autor:innen. Beteiligte Einrichtung: Emergency Department, Royal Hobart Hospital, Hobart, TAS 7000, Australia. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Research Future Fund.
Abstract (Originalsprache)
Objectives
To evaluate the accuracy and usability of emergency department (ED) clinician-assigned diagnostic codes across all four Tasmanian public hospitals.
Methods
We conducted a retrospective study of 300 ED presentations from all four public EDs in Tasmania. Two reviewers, a specialist emergency physician and a clinical research fellow, classified the accuracy of diagnostic codes across five levels which were then further classified into usable (levels 1–2) and unusable (levels 3–5). Rater agreement was evaluated. For accuracy and usability evaluation, conflicting reviewer classifications were removed. Associations between usability and patient, presentation, and site characteristics were evaluated using chi-square and Fisher’s exact tests.
Results
Overall rater agreement was moderate for both accuracy (69.3%, κ = 0.52) and usability (81.7%, κ = 0.58). Among 208 eligible presentations, 139 (66.8%) diagnostic codes were correct, 153 (73.6%) were acceptable for secondary use, 9 (4.3%) were clearly incorrect and 13 (6.3%) had insufficient documentation. Coding performance varied across hospitals, acuity, arrival mode, and representation intervals, with hospital-level usability ranging from 63.6% to 88.9%.
Conclusions
Across all four Tasmanian public EDs, 66.8% of diagnostic codes were accurate, 73.6% were appropriate for secondary use, and 4.3% were clearly incorrect, with moderate rater agreement for accuracy and usability (κ = 0.52 and κ = 0.58). These findings, together with marked between-hospital variation, underscore the context dependence and subjectivity of ED diagnostic coding. They support a cautious approach to using ED diagnostic codes for health service planning, performance reporting, and observational research, while highlighting the need to address barriers and opportunities to strengthen coding performance.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Emergency Department, Royal Hobart Hospital, Hobart, TAS 7000, Australia.
- Tasmanian School of Medicine, University of Tasmania, Hobart, TAS 7000, Australia.
- Menzies Institute for Medical Research, University of Tasmania, Hobart, TAS 7000, Australia.
- Tasmanian Emergency Medicine Research Institute, Hobart, TAS 7000, Australia.
ORCID-Profile: Viet Tran, Simone Page, Lauren Thurlow, Lizette Tredoux, Giles Barrington
Förderung
- Medical Research Future Fund
Zitieren
APA
Tran, V., Tham, E., Page, S., Thurlow, L., Tredoux, L., & Barrington, G. (2026). Accuracy and Usability of Emergency Department Diagnostic Codes: A Multicentre Observational Study. Diagnostics, 16(17), 2872. https://doi.org/10.3390/diagnostics16172872
Vancouver
Tran V, Tham E, Page S, Thurlow L, Tredoux L, Barrington G. Accuracy and Usability of Emergency Department Diagnostic Codes: A Multicentre Observational Study. Diagnostics. 2026;16(17):2872. doi:10.3390/diagnostics16172872
BibTeX
@article{Tran2026,
author = {Tran, Viet and Tham, Elizabeth and Page, Simone and Thurlow, Lauren and Tredoux, Lizette and Barrington, Giles},
title = {Accuracy and Usability of Emergency Department Diagnostic Codes: A Multicentre Observational Study},
journal = {Diagnostics},
year = {2026},
volume = {16},
number = {17},
pages = {2872},
doi = {10.3390/diagnostics16172872}
}
EUVIMED