Efficiency and Optimization of Iodinated Contrast Agents in Cerebral Aneurysm CT Angiography: A Systematic Review
Diagnostics · 21.08.2026 · 16 (16) · 2666
DOI: 10.3390/diagnostics16162666 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Diagnostics, online erschienen am 21.08.2026. Verfasst von Raluca-Maria Lezeu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Doctoral School of Biomedical Sciences, Faculty of Medicine and Pharmacy, University of Oradea, P-ta 1 Decembrie 10, 410087 Oradea, Romania. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Oradea, University of Oradea, Romania.
Abstract (Originalsprache)
Background/Objectives: The demand for reducing iodinated contrast agent (ICA) dose in cerebral CT angiography (CTA) for aneurysm detection has increased due to concerns over patient safety and image quality. The aim of this study is to systematically review the diagnostic accuracy, image quality, and dose efficiency of optimized ICA protocols in CTA for intracranial aneurysm detection. We also aimed to distinguish between direct diagnostic studies reporting aneurysm sensitivity/specificity and indirect technical studies, emphasizing patient-specific tailoring using cardiac output and lean body weight.
Methods
Following PRISMA 2020 guidelines, PubMed, Scopus, and Web of Science were searched up to 2 June 2026. Two reviewers independently screened studies, extracted data, and assessed risk of bias using QUADAS-2 and the NIH tool. Due to clinical and technical heterogeneity, a narrative synthesis was performed.
Results
Eleven studies comprising 716 patients were included. Low tube voltage (70–80 kVp) combined with reduced iodine load (8–30 mL, 3.2–9 gI) maintained diagnostic accuracy for aneurysms >3 mm compared to standard protocols. Iterative reconstruction and deep learning improved contrast-to-noise ratio by 23–45% at reduced dose. Technical studies showed feasibility of ultra-low-volume protocols but lacked aneurysm-specific DSA validation.
Conclusions
Reduced-contrast and low-kVp CTA protocols may preserve diagnostic performance for intracranial aneurysm detection while lowering iodine exposure. However, current evidence is limited by small sample sizes and heterogeneous protocols. Prospective, aneurysm-specific validation is required before clinical implementation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Doctoral School of Biomedical Sciences, Faculty of Medicine and Pharmacy, University of Oradea, P-ta 1 Decembrie 10, 410087 Oradea, Romania.
- Department of Preclinical Sciences, Faculty of Medicine and Pharmacy, University of Oradea, P-ta 1 Decembrie 10, 410087 Oradea, Romania.
Förderung
- University of Oradea
- University of Oradea, Romania
Zitieren
APA
Lezeu, R. M., Chirla, R., & Cavalu, S. D. (2026). Efficiency and Optimization of Iodinated Contrast Agents in Cerebral Aneurysm CT Angiography: A Systematic Review. Diagnostics, 16(16), 2666. https://doi.org/10.3390/diagnostics16162666
Vancouver
Lezeu RM, Chirla R, Cavalu SD. Efficiency and Optimization of Iodinated Contrast Agents in Cerebral Aneurysm CT Angiography: A Systematic Review. Diagnostics. 2026;16(16):2666. doi:10.3390/diagnostics16162666
BibTeX
@article{Lezeu2026,
author = {Lezeu, Raluca-Maria and Chirla, Razvan and Cavalu, Simona Daniela},
title = {Efficiency and Optimization of Iodinated Contrast Agents in Cerebral Aneurysm CT Angiography: A Systematic Review},
journal = {Diagnostics},
year = {2026},
volume = {16},
number = {16},
pages = {2666},
doi = {10.3390/diagnostics16162666}
}
EUVIMED