Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 31.07.2026. Verfasst von Aslı Aksoy Gündoğdu und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Faculty of Medicine, Tekirdağ Namık Kemal University, Tekirdağ 59030, Turkey. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Circulating trace-element differences have been reported in neurodegenerative disorders, but data in multiple system atrophy (MSA) are scarce. We compared eleven trace elements and two operationally defined exploratory composite indices between patients with MSA and controls.

Methods

This case–control study included 30 patients with MSA and 30 frequency-matched controls. Eleven elements were quantified by ICP-MS. The raw Metal Burden Index (MBI; mean of aluminum, lead, cadmium, manganese, and arsenic) and Neurotoxic Metal Score (NMS) were calculated. Component-level decomposition was performed, and an aluminum-excluded index and component-standardized MBI (MBIz) were evaluated as sensitivity analyses.

Results

Patients with MSA had higher aluminum and copper and lower iron and zinc than controls (all p < 0.001, Bonferroni-corrected; absolute Cohen’s d = 3.39–3.85). The raw MBI was higher in MSA (p < 0.001, d = 1.38) and remained associated with MSA status after age/sex adjustment (OR = 5.50, 95% CI 2.25–13.47 per 1-SD increase). Aluminum accounted for 114.6% of the MBI difference; the aluminum-excluded index did not differ. MBIz was higher in MSA (p < 0.001, d = 0.95). Exploratory ROC analyses showed apparent separation for raw MBI, aluminum, and copper without establishing validated diagnostic thresholds. No statistically significant correlations with disease severity or duration were observed; estimates were imprecise.

Conclusions

MSA was associated with higher serum aluminum and copper and lower iron and zinc. The raw MBI predominantly reflected the aluminum signal; its incremental value beyond individual elements remains unproven. Findings require validation in disease-control and multicenter cohorts.

Schlagwörter

Stichwörter der Autor:innen

ICP-MSMetal Burden Indexaluminumcase–control studycoppermultiple system atrophytrace elements

Autor:innen und Institutionen

  • Department of Neurology, Faculty of Medicine, Tekirdağ Namık Kemal University, Tekirdağ 59030, Turkey.
  • Department of Neurology, Faculty of Medicine, Istanbul Aydın University, Istanbul 34295, Turkey.

ORCID-Profile: Aslı Aksoy Gündoğdu

Zitieren

APA

Gündoğdu, A. A., & Demiryürek, B. E. (2026). Serum Trace-Element Profiles and Exploratory Composite Indices in Multiple System Atrophy: A Case–Control Study. Diagnostics, 16(15), 2420. https://doi.org/10.3390/diagnostics16152420

Vancouver

Gündoğdu AA, Demiryürek BE. Serum Trace-Element Profiles and Exploratory Composite Indices in Multiple System Atrophy: A Case–Control Study. Diagnostics. 2026;16(15):2420. doi:10.3390/diagnostics16152420

BibTeX
@article{Gndodu2026,
  author = {Gündoğdu, Aslı Aksoy and Demiryürek, Bekir Enes},
  title = {Serum Trace-Element Profiles and Exploratory Composite Indices in Multiple System Atrophy: A Case–Control Study},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {15},
  pages = {2420},
  doi = {10.3390/diagnostics16152420}
}
Kostenlos starten →