EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparative Analysis of Four Commercially Available Artificial Intelligence Software for Brain Volumetry

Vergleich von vier kommerziell verfügbaren KI-Softwarelösungen zur Hirnvolumetrie

Gaspare Saltarelli iD, Giovanni Di Cerbo, Antonio Innocenzi, Marco De Chellis, Federico Bruno iD, Alessandra Splendiani iD, Ernesto Di Cesare iD

Diagnostics · 29.07.2026 · 16 (15) · 2383

DOI: 10.3390/diagnostics16152383 ↗

Auf einen Blick

Verglichen wurden vier klinisch verfügbare KI-Tools zur automatisierten Hirnvolumetrie bei 47 Erwachsenen. Die absoluten Volumina unterschieden sich je nach Software deutlich und waren nicht direkt austauschbar.

Fragestellung

Wie groß sind Inter-Software-Variabilität, Übereinstimmung und Austauschbarkeit zwischen vier KI-gestützten Tools zur Hirnvolumetrie?

Methode

Einzentrische retrospektive Vergleichsstudie mit 4 Tools an identischen 3D-T1-MRTs; Auswertung mit ANOVA mit Bonferroni-Post-hoc-Tests und ICC mit 95 %-KI.

Ergebnisse

Alle Tests waren signifikant (p < 0,001). icobrain dm® lieferte meist die größten, Neurophet AQUA® die kleinsten Volumina. Die Übereinstimmung war strukturabhängig; bei den Seitenventrikeln war sie am besten (ICC ≈ 0,92 [0,85–0,96]).

Schlussfolgerung der Autor:innen

Absolute Volumina sind zwischen den Plattformen nicht direkt austauschbar, die relative Rangfolge der Personen bleibt aber weitgehend erhalten.

Kernaussagen

  • Alle 4 Tools zeigten methodenabhängige Skalierungsunterschiede
  • Austauschbarkeit der absoluten Volumina war eingeschränkt
  • Verlaufskontrollen sollten mit derselben Plattform erfolgen

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 29.07.2026. Verfasst von Gaspare Saltarelli und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, 67100 L'Aquila, Italy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Automated brain volumetry is increasingly integrated into the work-up of several neurological disorders, yet between-software variability may limit the interchangeability of absolute measures. This study aimed to assess inter-software variability, agreement, and interchangeability among four clinically available AI-based brain volumetry tools.

Methods

We conducted a single-center, retrospective comparison of four clinically available tools (Neurophet AQUA®, icobrain dm®, mdbrain®, Pixyl®) applied to identical 3D T1-weighted MRI examinations (IR-FSPGR, 1 mm isotropic) acquired at 3 T in 47 adults referred for tremor evaluation. Absolute volumes (mL) were extracted for hippocampus, temporal, parietal, and frontal lobes, lateral ventricles, and total brain volume; the occipital lobe was analyzed where reported (three tools). Region-wise complete-case analyses were performed. Repeated-measures ANOVA with Bonferroni post hoc tests assessed systematic differences, and intraclass correlation coefficients (two-way mixed, consistency) were reported as single- and average-measure with 95% CIs to quantify agreement.

Results

Across regions, all tests were significant (p < 0.001), indicating method-dependent scale offsets typically on the order of ~20–40%. A consistent pattern emerged: icobrain dm® yielded the largest absolute volumes, Neurophet AQUA® the lowest, mdbrain® tended to be lower for parietal measurements, and Pixyl® was generally intermediate. Agreement was structure-dependent: excellent for lateral ventricles (single-measure ICC ≈ 0.92 [0.85–0.96]; average-measure ICC ≈ 0.98 [0.96–0.99]); good-to-excellent for temporal and parietal lobes (average-measure ICC ≈ 0.83–0.84); moderate-to-good for hippocampus and total brain volume (TBV) (average-measure ICC ≈ 0.79–0.81), with only moderate single-measure agreement for TBV (ICC ≈ 0.51); and lowest for the frontal lobe (single-measure ICC ≈ 0.43 [0.23–0.65]; average-measure ICC ≈ 0.75 [0.54–0.88]). In the occipital lobe (three tools), Neurophet AQUA® yielded substantially smaller values than icobrain dm® and mdbrain® (p < 0.0001).

Conclusions

Overall, absolute volumetric outputs are not directly interchangeable across platforms, but relative subject ranking is largely preserved; platform-consistent analysis is advisable for longitudinal monitoring, and cross-site studies should implement calibration/harmonization before pooling data.

Schlagwörter

Stichwörter der Autor:innen

artificial intelligenceautomated segmentationbrain volumetryimage processingmagnetic resonance imagingmovement disorders

Autor:innen und Institutionen

  • Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, 67100 L'Aquila, Italy.

ORCID-Profile: Gaspare Saltarelli, Federico Bruno, Alessandra Splendiani, Ernesto Di Cesare

Zitieren

APA

Saltarelli, G., Di Cerbo, G., Innocenzi, A., De Chellis, M., Bruno, F., Splendiani, A., & Di Cesare, E. (2026). Comparative Analysis of Four Commercially Available Artificial Intelligence Software for Brain Volumetry. Diagnostics, 16(15), 2383. https://doi.org/10.3390/diagnostics16152383

Vancouver

Saltarelli G, Di Cerbo G, Innocenzi A, De Chellis M, Bruno F, Splendiani A, et al. Comparative Analysis of Four Commercially Available Artificial Intelligence Software for Brain Volumetry. Diagnostics. 2026;16(15):2383. doi:10.3390/diagnostics16152383

BibTeX
@article{Saltarelli2026,
  author = {Saltarelli, Gaspare and Di Cerbo, Giovanni and Innocenzi, Antonio and De Chellis, Marco and Bruno, Federico and Splendiani, Alessandra and Di Cesare, Ernesto},
  title = {Comparative Analysis of Four Commercially Available Artificial Intelligence Software for Brain Volumetry},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {15},
  pages = {2383},
  doi = {10.3390/diagnostics16152383}
}
Kostenlos starten →