EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Tomographic 3D Ultrasound for Thyroid Volumetry—A Comparison Between Multiplanar 2D and 3D Imaging Methods

Robert Roth iD, Zoe Reinke iD, Martin Siedlecki, Jan Luitjens, Martin Hügle iD, Johanna S Enke iD, Christian Liska, Laura-Marie Feitelson, Constantin Lapa iD, Thomas Kroencke iD, Robert Bauer, Thomas Wendler iD

Diagnostics · 25.07.2026 · 16 (15) · 2329

DOI: 10.3390/diagnostics16152329 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 25.07.2026. Verfasst von Robert Roth und 11 weiteren Autor:innen. Beteiligte Einrichtung: PIUR Imaging GmbH, 1070 Vienna, Austria. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bavarian State Ministry of Economics, Regional Development and Energy.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate thyroid volume measurement is essential for diagnosing and monitoring thyroid disorders and for determining radioiodine therapy dosage. The ellipsoid method applied to two-dimensional B-mode ultrasound (Bmode-2D-US) is the most prevalent clinical approach, yet it is known to suffer from high observer dependence and limited accuracy. Tracked three-dimensional ultrasound (3D-US) is a promising radiation-free alternative, but direct comparisons across modalities under controlled conditions remain scarce.

Methods

A custom-built anthropomorphic multi-modality phantom was constructed containing six anatomically realistic thyroid lobe samples molded from segmented MRI data, with ground truth volumes verified by the suspension method and 3D surface scanning. Volume measurements were performed by six observers of varying experience using Bmode-2D-US, electromagnetically tracked 3D-US (EM-3D-US), inertial-measurement-unit-tracked 3D-US (IMU-3D-US), and optically tracked 3D-US (Opt-3D-US), as well as computed tomography (CT) and magnetic resonance imaging (MRI). Inter- and intraobserver variability were assessed using modified Bland–Altman analysis.

Results

All three 3D-US methods reduced inter- and intraobserver variability compared to Bmode-2D-US, achieving variability comparable to CT and lower than MRI. Mean accuracy was similar across 3D-US, CT, and MRI. Bmode-2D-US showed strong observer dependence, with operator experience having the most pronounced effect on this method. Among tracked methods, EM-3D-US and Opt-3D-US were least sensitive to operator movement quality, while IMU-3D-US showed somewhat higher sensitivity.

Conclusions

Tracked 3D-US is a promising radiation-free alternative to conventional Bmode-2D-US for thyroid volumetry, offering improved reproducibility and accuracy across operators of varying experience in this phantom-based evaluation.

Schlagwörter

Stichwörter der Autor:innen

ellipsoid methodinterobserver variabilitymulti-modality phantomreproducibilitythyroid volumetrytissue-mimicking materialtracked 3D ultrasound

Autor:innen und Institutionen

  • PIUR Imaging GmbH, 1070 Vienna, Austria.
  • Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine, University of Augsburg, 86156 Augsburg, Germany.
  • Digital Medicine, Faculty of Medicine, University of Augsburg, 86156 Augsburg, Germany.
  • Nuclear Medicine, Faculty of Medicine, University of Augsburg, 86156 Augsburg, Germany.
  • Bavarian Cancer Research Center (BZKF), 86156 Augsburg, Germany.
  • Center for Advanced Analytics and Predictive Sciences (CAAPS), University of Augsburg, 86159 Augsburg, Germany.

ORCID-Profile: Robert Roth, Zoe Reinke, Martin Hügle, Johanna S Enke, Constantin Lapa, Thomas Kroencke, Thomas Wendler

Förderung

  • Bavarian State Ministry of Economics, Regional Development and Energy

Zitieren

APA

Roth, R., Reinke, Z., Siedlecki, M., Luitjens, J., Hügle, M., Enke, J. S., Liska, C., Feitelson, L. M., Lapa, C., Kroencke, T., Bauer, R., & Wendler, T. (2026). Tomographic 3D Ultrasound for Thyroid Volumetry—A Comparison Between Multiplanar 2D and 3D Imaging Methods. Diagnostics, 16(15), 2329. https://doi.org/10.3390/diagnostics16152329

Vancouver

Roth R, Reinke Z, Siedlecki M, Luitjens J, Hügle M, Enke JS, et al. Tomographic 3D Ultrasound for Thyroid Volumetry—A Comparison Between Multiplanar 2D and 3D Imaging Methods. Diagnostics. 2026;16(15):2329. doi:10.3390/diagnostics16152329

BibTeX
@article{Roth2026,
  author = {Roth, Robert and Reinke, Zoe and Siedlecki, Martin and Luitjens, Jan and Hügle, Martin and Enke, Johanna S and Liska, Christian and Feitelson, Laura-Marie and Lapa, Constantin and Kroencke, Thomas and Bauer, Robert and Wendler, Thomas},
  title = {Tomographic 3D Ultrasound for Thyroid Volumetry—A Comparison Between Multiplanar 2D and 3D Imaging Methods},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {15},
  pages = {2329},
  doi = {10.3390/diagnostics16152329}
}
Kostenlos starten →