EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitScoping ReviewOpen Access · CC BY 4.0

Tumour Localisation Technologies in Colorectal Cancer Surgery: A Scoping Review of Marking and Detection Methods

Mircea Fulea iD, Mihaela Mocan iD, Mircea Murar iD, Bogdan Mocan iD, Vasile Bințințan

Diagnostics · 23.06.2026 · 16 (13) · 1952

DOI: 10.3390/diagnostics16131952 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Diagnostics, online erschienen am 23.06.2026. Verfasst von Mircea Fulea und 4 weiteren Autor:innen. Beteiligte Einrichtung: Design Engineering and Robotics Department, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania. Die Arbeit nennt 90 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Unitatea Executiva Pentru Finantarea Invatamantului Superior Si A Cercetarii Stiintifice Universitare, Romanian Ministry of Research, Innovation and Digitization, CCCDI—UEFISCDI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Precise intraoperative localisation of small colorectal tumours during laparoscopic surgery remains challenging due to absent tactile feedback and subserosal tumour location. Current standard methods, particularly India ink tattooing, demonstrate 15–30% failure rates for lesions less than 10 mm, leading to prolonged operative times, incomplete resections, and re-operations. Multiple emerging technologies promise improved localisation, yet comparative evidence remains fragmented.

Objective

To map and characterise the current landscape of intraoperative marking and identification technologies for small colorectal tumour localisation during laparoscopic surgery, with emphasis on radiofrequency-based methods and alternative approaches, and to identify evidence gaps guiding future research.

Methods

Following PRISMA-ScR guidelines, we systematically searched PubMed, Web of Science, and Scopus databases from January 2000 through December 2025 for studies evaluating tumour localisation technologies in colorectal cancer surgery, including primary tumour localisation during laparoscopic colectomy and localisation of colorectal liver metastases during hepatic surgery, or transferable anatomical applications with documented translational potential to colorectal surgery. Two independent reviewers screened all records, with discrepancies resolved through discussion and a third senior reviewer consulted for unresolved disagreements; data were extracted on technical performance, safety, feasibility, cost-effectiveness, usability, innovation potential, and evidence quality.

Results

We included 89 studies comprising 18 colorectal-specific articles and 71 transferable/GI-adjacent studies. Detection success rates ranged from 71% to 100% across modalities. Near-infrared fluorescence with indocyanine green demonstrated the strongest clinical evidence with 75–100% detection across eight colorectal studies encompassing 2134 procedures and seamless workflow integration. Radiofrequency identification systems achieved 91.9–99% detection in feasibility studies with promising tissue penetration of 15–35 mm but limited colorectal validation. Electromagnetic navigation excelled in rigid organs with 85–98% success but showed degraded performance in mobile bowel at 71–75%. Critical evidence gaps included absent head-to-head comparative trials, non-standardised outcome metrics limiting cross-study comparability, and limited long-term safety data with only 14 studies providing follow-up exceeding six months.

Conclusions

ICG fluorescence represents the most clinically mature technology identified, representing a priority candidate for colorectal-specific validation in challenging localisation scenarios. RFID systems demonstrate promising characteristics justifying prioritised research investment through adequately powered comparative trials. Future research must emphasise consortium-based comparative effectiveness studies, standardised outcome metrics, and integration with robotic and AI-assisted surgical platforms to accelerate clinical translation.

Schlagwörter

Stichwörter der Autor:innen

colorectal cancer surgerycolorectal neoplasmselectromagnetic navigationindocyanine greenintraoperative localisationmagnetic seed localisationminimally invasive surgerynear-infrared fluorescencepreoperative markingradiofrequency identificationscoping review

Autor:innen und Institutionen

  • Design Engineering and Robotics Department, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania.
  • Department of Internal Medicine, Iuliu Hațieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania.
  • Department of Surgery, Iuliu Hațieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania.

ORCID-Profile: Mircea Fulea, Mihaela Mocan, Mircea Murar, Bogdan Mocan

Förderung

  • Unitatea Executiva Pentru Finantarea Invatamantului Superior Si A Cercetarii Stiintifice Universitare
  • Romanian Ministry of Research, Innovation and Digitization, CCCDI—UEFISCDI

Zitieren

APA

Fulea, M., Mocan, M., Murar, M., Mocan, B., & Bințințan, V. (2026). Tumour Localisation Technologies in Colorectal Cancer Surgery: A Scoping Review of Marking and Detection Methods. Diagnostics, 16(13), 1952. https://doi.org/10.3390/diagnostics16131952

Vancouver

Fulea M, Mocan M, Murar M, Mocan B, Bințințan V. Tumour Localisation Technologies in Colorectal Cancer Surgery: A Scoping Review of Marking and Detection Methods. Diagnostics. 2026;16(13):1952. doi:10.3390/diagnostics16131952

BibTeX
@article{Fulea2026,
  author = {Fulea, Mircea and Mocan, Mihaela and Murar, Mircea and Mocan, Bogdan and Bințințan, Vasile},
  title = {Tumour Localisation Technologies in Colorectal Cancer Surgery: A Scoping Review of Marking and Detection Methods},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {13},
  pages = {1952},
  doi = {10.3390/diagnostics16131952}
}
Kostenlos starten →