EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Intralenticular Metallic Foreign Body After Pediatric Ocular Trauma

Bogumiła Wójcik-Niklewska iD, Adriana Błaszczyk-Windak, Martyna Marcoll, Anna Kamińska, Dorota Wyględowska-Promieńska iD

Diagnostics · 17.06.2026 · 16 (12) · 1889

DOI: 10.3390/diagnostics16121889 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 17.06.2026. Verfasst von Bogumiła Wójcik-Niklewska und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Ophthalmology, Faculty of Medical Sciences in Katowice, Medical University of Silesia, 40-514 Katowice, Poland. Die Arbeit nennt 7 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Intraocular foreign bodies penetrating the eye can lead to serious complications, including endophthalmitis, and therefore require urgent removal. We present the case of a 9-year-old boy with an intraocular foreign body lodged in the lens with a corneal flap wound. The injury occurred while hammering a bicycle frame. The patient presented with sudden pain, tearing, and decreased visual acuity in the left eye. On admission, the left eye distance best-corrected visual acuity (BCVA) was 0.4 and intraocular pressure (IOP) was 17 mmHg. Slit-lamp examination of the left eye revealed a full-thickness corneal flap wound, a traumatic cataract, and a foreign body located centrally within the lens. B-scan ultrasonography demonstrated an echogenic focus within the lens consistent with an intralenticular metallic foreign body, with a normal posterior segment, a regular appearance of the optic disc, and an attached retina. The patient underwent phacoaspiration of the traumatic cataract with intraocular lens implantation and simultaneous removal of the foreign body. Given the corneal flap wound located in the visual axis and the absence of ocular hypotony, the decision was made not to place a corneal suture. At discharge, BCVA improved to 1.0, with IOP of 17 mmHg and normal fundus appearance.

Schlagwörter

Stichwörter der Autor:innen

childcorneal injurieseye foreign bodiesintraocularlens implantation

Autor:innen und Institutionen

  • Department of Pediatric Ophthalmology, Faculty of Medical Sciences in Katowice, Medical University of Silesia, 40-514 Katowice, Poland.
  • Department of Pediatric Ophthalmology, Professor Kornel Gibiński University Clinical Center, Medical University of Silesia, 40-514 Katowice, Poland.
  • Students Scientific Society, Department of Ophthalmology, Faculty of Medical Sciences in Katowice, Medical University of Silesia, 40-514 Katowice, Poland.
  • Department of Ophthalmology, Faculty of Medical Sciences in Katowice, Medical University of Silesia, 40-514 Katowice, Poland.
  • Department of Ophthalmology, Professor Kornel Gibiński University Clinical Center, Medical University of Silesia, 40-514 Katowice, Poland.

ORCID-Profile: Bogumiła Wójcik-Niklewska, Dorota Wyględowska-Promieńska

Zitieren

APA

Wójcik-Niklewska, B., Błaszczyk-Windak, A., Marcoll, M., Kamińska, A., & Wyględowska-Promieńska, D. (2026). Intralenticular Metallic Foreign Body After Pediatric Ocular Trauma. Diagnostics, 16(12), 1889. https://doi.org/10.3390/diagnostics16121889

Vancouver

Wójcik-Niklewska B, Błaszczyk-Windak A, Marcoll M, Kamińska A, Wyględowska-Promieńska D. Intralenticular Metallic Foreign Body After Pediatric Ocular Trauma. Diagnostics. 2026;16(12):1889. doi:10.3390/diagnostics16121889

BibTeX
@article{WjcikNiklewska2026,
  author = {Wójcik-Niklewska, Bogumiła and Błaszczyk-Windak, Adriana and Marcoll, Martyna and Kamińska, Anna and Wyględowska-Promieńska, Dorota},
  title = {Intralenticular Metallic Foreign Body After Pediatric Ocular Trauma},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {12},
  pages = {1889},
  doi = {10.3390/diagnostics16121889}
}
Kostenlos starten →