EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Dynamic Contrast-Enhanced Ultrasound for Carotid Plaque Characterization: An Algorithm-Aware Technical Review

Nicola Morelli iD, Marco Spallazzi, Marina Biondi, Eugenia Rota iD, Lucia Mazza, Paolo Immovilli, Davide Colombi iD

Diagnostics · 11.06.2026 · 16 (12) · 1808

DOI: 10.3390/diagnostics16121808 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Diagnostics, online erschienen am 11.06.2026. Verfasst von Nicola Morelli und 6 weiteren Autor:innen. Beteiligte Einrichtung: Neuroradiology Unit, Guglielmo da Saliceto Hospital, 29121 Piacenza, Italy. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Carotid artery disease has traditionally been assessed according to luminal stenosis, although plaques with similar narrowing may differ substantially in biological activity and clinical risk. Intraplaque neovascularization is a key feature of plaque vulnerability, reflecting microvascular proliferation and its association with inflammation, hemorrhage, and structural destabilization. Dynamic contrast-enhanced ultrasound (DCE-US) offers a real-time, radiation-free method for evaluating intraplaque enhancement kinetics using strictly intravascular microbubble agents. However, its broader use in carotid plaque imaging remains limited by variability in acquisition protocols, contrast administration, signal processing, curve fitting, and parameter interpretation. This technical review clarifies the main analytical approaches used in carotid DCE-US, distinguishing bolus-based wash-in/wash-out analysis from destruction–replenishment modeling. Bolus analysis describes first-pass microbubble transit through the plaque microvasculature and commonly provides parameters such as peak intensity, wash-in slope, area under the curve, and time to peak. Destruction–replenishment analysis evaluates post-destruction refill under stable or quasi-stable contrast conditions and relies on model-based estimation of plateau intensity and the replenishment rate. Because these approaches interrogate different kinetic regimes, their outputs should not be considered interchangeable, even when similar terms are used across studies. Particular emphasis is placed on the operational meaning of quantitative and semi-quantitative parameters, the assumptions underlying curve modeling, and the methodological consequences of ROI placement, motion correction, acoustic settings, and fitting constraints. Rather than proposing a universal acquisition protocol, this article provides practical principles for acquisition, analysis, and reporting, helping radiologists, neuroradiologists, neurologists, and vascular imaging specialists understand the processing steps, algorithmic assumptions, and model-dependent choices underlying software-derived curves and parameters. By making this analytical layer more explicit, the review seeks to support a transparent, reproducible, and biologically coherent approach to quantitative carotid plaque characterization.

Schlagwörter

Stichwörter der Autor:innen

carotid plaquecontrast-enhanced ultrasounddynamic contrast-enhanced ultrasoundimaging biomarkersintraplaque neovascularizationquantitative plaque characterizationsignal modeling

Autor:innen und Institutionen

  • Neuroradiology Unit, Guglielmo da Saliceto Hospital, 29121 Piacenza, Italy.
  • Neurology Unit, University of Parma, 43121 Parma, Italy.
  • Neurology Unit, San Giacomo Hospital, 15067 Novi Ligure, Italy.
  • Neurology Unit, Guglielmo da Saliceto Hospital, 29121 Piacenza, Italy.
  • Department of Diagnostic Imaging, Centro Diagnostico Rocca, 29121 Piacenza, Italy.

ORCID-Profile: Nicola Morelli, Eugenia Rota, Davide Colombi

Zitieren

APA

Morelli, N., Spallazzi, M., Biondi, M., Rota, E., Mazza, L., Immovilli, P., & Colombi, D. (2026). Dynamic Contrast-Enhanced Ultrasound for Carotid Plaque Characterization: An Algorithm-Aware Technical Review. Diagnostics, 16(12), 1808. https://doi.org/10.3390/diagnostics16121808

Vancouver

Morelli N, Spallazzi M, Biondi M, Rota E, Mazza L, Immovilli P, et al. Dynamic Contrast-Enhanced Ultrasound for Carotid Plaque Characterization: An Algorithm-Aware Technical Review. Diagnostics. 2026;16(12):1808. doi:10.3390/diagnostics16121808

BibTeX
@article{Morelli2026,
  author = {Morelli, Nicola and Spallazzi, Marco and Biondi, Marina and Rota, Eugenia and Mazza, Lucia and Immovilli, Paolo and Colombi, Davide},
  title = {Dynamic Contrast-Enhanced Ultrasound for Carotid Plaque Characterization: An Algorithm-Aware Technical Review},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {12},
  pages = {1808},
  doi = {10.3390/diagnostics16121808}
}
Kostenlos starten →