Sinus- and Sequence-Specific Diagnostic Performance of Routine Unenhanced Brain MRI in Dural Venous Sinus Thrombosis
Diagnostics · 08.06.2026 · 16 (12) · 1771
DOI: 10.3390/diagnostics16121771 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 08.06.2026. Verfasst von Mehmet Karagulle und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Basaksehir Cam and Sakura City Hospital, Istanbul 34480, Türkiye. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Dural venous sinus thrombosis (DVST) is an uncommon but potentially life-threatening cerebrovascular disorder requiring early diagnosis to prevent serious complications. Although CE-MRV is the reference standard, routine brain MRI is often the first imaging study in patients with nonspecific neurological symptoms, and the sinus-specific diagnostic performance of individual sequences remains incompletely defined.
Purpose
To evaluate the diagnostic performance and inter-reader agreement of routine brain MRI sequences for DVST detection using a sinus-specific framework.
Methods
This retrospective case–control study included 140 patients (34 with DVST, 106 age-matched controls) imaged on 1.5 T and 3.0 T scanners. Two blinded neuroradiologists evaluated six unenhanced sequences (sagittal/axial T1WI, T2WI, FLAIR, DWI [b = 1000 s/mm2], and SWI) across four dural sinuses, using CE-MRV and CE-3D T1WI as the reference standards. Logistic regression and Cohen’s κ assessed diagnostic performance and inter-reader agreement, respectively.
Results
Globally, DWI with FLAIR achieved 97.9% accuracy, 91.2% sensitivity, and 100% specificity (AUC = 0.997). Optimal sequences varied by sinus: sagittal T1WI with SWI for the superior sagittal sinus (accuracy = 99.3%), DWI with SWI for the transverse sinus (97.9%), DWI with FLAIR and T2WI for the sigmoid sinus (98.6%), and SWI with axial T1 for the straight sinus (100%). Inter-reader agreement was substantial to almost perfect for routine sequences (mean κ = 0.874) and almost perfect for CE-MRV and CE-3D T1WI (κ = 0.98).
Conclusions
Routine brain MRI provides reliable DVST detection with a sinus-tailored multisequence strategy. DWI and FLAIR offer robust diagnostic performance in global evaluation, while T1WI, SWI and T2WI add segment-specific value, reserving CE-MRV and CE-3D T1WI for equivocal or clinically suspicious cases.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Basaksehir Cam and Sakura City Hospital, Istanbul 34480, Türkiye.
ORCID-Profile: Mehmet Karagulle, Tahsin Benlice, Tuba Banaz, Burak Kocak
Zitieren
APA
Karagulle, M., Benlice, T., Banaz, T., & Kocak, B. (2026). Sinus- and Sequence-Specific Diagnostic Performance of Routine Unenhanced Brain MRI in Dural Venous Sinus Thrombosis. Diagnostics, 16(12), 1771. https://doi.org/10.3390/diagnostics16121771
Vancouver
Karagulle M, Benlice T, Banaz T, Kocak B. Sinus- and Sequence-Specific Diagnostic Performance of Routine Unenhanced Brain MRI in Dural Venous Sinus Thrombosis. Diagnostics. 2026;16(12):1771. doi:10.3390/diagnostics16121771
BibTeX
@article{Karagulle2026,
author = {Karagulle, Mehmet and Benlice, Tahsin and Banaz, Tuba and Kocak, Burak},
title = {Sinus- and Sequence-Specific Diagnostic Performance of Routine Unenhanced Brain MRI in Dural Venous Sinus Thrombosis},
journal = {Diagnostics},
year = {2026},
volume = {16},
number = {12},
pages = {1771},
doi = {10.3390/diagnostics16121771}
}
EUVIMED