Diagnostic Potential of Apparent Diffusion Coefficient-Based Lymph Node Classification in Breast Cancer Patients Undergoing [18F]FDG-PET/MRI
Diagnostics · 02.06.2026 · 16 (11) · 1712
DOI: 10.3390/diagnostics16111712 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 02.06.2026. Verfasst von Helena A Peters und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Medical Faculty, University Düsseldorf, 40225 Düsseldorf, Germany. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft (DFG), the German Research Foundation.
Themen: Onkologische Pflege
Abstract (Originalsprache)
Background/Objectives: To evaluate the diagnostic potential of apparent diffusion coefficient (ADC) values for classifying lymph nodes as benign or malignant in breast cancer patients undergoing [18F]FDG-PET/MRI staging.
Methods
Mean ADC values and short-axis diameters (±standard deviation) of 199 thoracic lymph nodes in 113 newly diagnosed breast cancer patients were retrospectively analyzed. All patients underwent [18F]FDG-PET/MRI staging, between July 2017 and June 2021. A node-by-node comparison was performed with respect to pathological node status. Nodal FDG uptake in whole-body [18F]FDG-PET/MRI served as reference standard for nodal malignancy. Group comparison using Mann–Whitney U test, receiver operating characteristic curve (ROC) analysis and diagnostic performance were calculated. p values below 0.05 were defined as statistically significant. Confidence intervals (CI; 95%) were calculated.
Results
Ninety-three lymph nodes were FDG-negative while 106 lymph nodes were FDG-positive. FDG-negative lymph nodes had significantly lower short-axis diameters ((5.1 ± 1.5 mm versus 12.3 ± 5.3 mm); p < 0.01; U: 405.50; Z: −11.24). ADC values were significantly lower in FDG-positive lymph nodes (0.72 ± 0.14 × 10−3 mm2/s) than in FDG-negative lymph nodes ((1.18 ± 0.18 × 10−3 mm2/s); p < 0.01; U: 173.00; Z: −11.80). ROC analysis and Youden’s index revealed an ADC cut-off of 0.95 × 10−3 mm2/s (AUC: 0.98; p < 0.01; 95% CI: 0.96–1.01). According to the calculated cut-off, sensitivity, specificity, and accuracy of ADC values for differentiating FDG-negative from FDG-positive lymph nodes were 98%, 97% and 97%, respectively.
Conclusions
ADC values derived from MRI were significantly associated with FDG uptake in this retrospective cohort and may serve as a complementary imaging biomarker for lymph node characterization.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University Düsseldorf, 40225 Düsseldorf, Germany.
- Department of Gynecology, Medical Faculty, University Düsseldorf, 40225 Düsseldorf, Germany.
- Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen and German Cancer Consortium (DKTK), 45147 Essen, Germany.
- High-Field and Hybrid MR Imaging, University Hospital Essen, 45147 Essen, Germany.
- Erwin L. Hahn Institute for MR Imaging, University of Duisburg-Essen, 45141 Essen, Germany.
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, 45147 Essen, Germany.
ORCID-Profile: Helena A Peters, Matthias Boschheidgen, Frederic Dietzel, Svjetlana Mohrmann, Peter Minko, Kai Jannusch
Förderung
- Deutsche Forschungsgemeinschaft (DFG), the German Research Foundation
Zitieren
APA
Peters, H. A., Scheuer, M., Weiss, D., Boschheidgen, M., Ivan, V. L., Dietzel, F., Mohrmann, S., Ruckhäberle, E., Herrmann, K., Quick, H. H., Milosevic, A., Minko, P., Kirchner, J., Umutlu, L., Antoch, G., & Jannusch, K. (2026). Diagnostic Potential of Apparent Diffusion Coefficient-Based Lymph Node Classification in Breast Cancer Patients Undergoing [18F]FDG-PET/MRI. Diagnostics, 16(11), 1712. https://doi.org/10.3390/diagnostics16111712
Vancouver
Peters HA, Scheuer M, Weiss D, Boschheidgen M, Ivan VL, Dietzel F, et al. Diagnostic Potential of Apparent Diffusion Coefficient-Based Lymph Node Classification in Breast Cancer Patients Undergoing [18F]FDG-PET/MRI. Diagnostics. 2026;16(11):1712. doi:10.3390/diagnostics16111712
BibTeX
@article{Peters2026,
author = {Peters, Helena A and Scheuer, Marie and Weiss, Daniel and Boschheidgen, Matthias and Ivan, Vivien Lorena and Dietzel, Frederic and Mohrmann, Svjetlana and Ruckhäberle, Eugen and Herrmann, Ken and Quick, Harald H and Milosevic, Aleksandar and Minko, Peter and Kirchner, Julian and Umutlu, Lale and Antoch, Gerald and Jannusch, Kai},
title = {Diagnostic Potential of Apparent Diffusion Coefficient-Based Lymph Node Classification in Breast Cancer Patients Undergoing [18F]FDG-PET/MRI},
journal = {Diagnostics},
year = {2026},
volume = {16},
number = {11},
pages = {1712},
doi = {10.3390/diagnostics16111712}
}