EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Negative Contrast Esophagography Does Not Exclude Dehiscence After Boerhaave Repair: Complementary Low-Insufflation Carbon Dioxide Endoscopy

Hee Suk Jung, Gong Min Rim iD, Young Mog Shim, Kwan Wook Kim

Diagnostics · 28.05.2026 · 16 (11) · 1670

DOI: 10.3390/diagnostics16111670 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 28.05.2026. Verfasst von Hee Suk Jung und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic and Cardiovascular Surgery, CHA Bundang Medical Center, CHA University, 59 Yatap-ro, Bundang-gu, Seongnam-si 13496, Republic o…. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

After repair of Boerhaave syndrome, assessment of repair integrity is important because occult dehiscence may progress to mediastinitis or pleural sepsis. Water-soluble contrast esophagography is widely used before resuming oral intake, but absence of extravasation does not necessarily exclude a small or contained defect. We report a 59-year-old man with post-emetic distal esophageal rupture treated by emergency primary repair with pleural-flap buttress and drainage. Although clinically stable, contrast esophagography on postoperative day (POD) 7 showed no extravasation. Because feeding decisions required greater structural confidence, low-insufflation carbon dioxide esophagogastroduodenoscopy was performed on POD 9 and revealed focal suture-line dehiscence. Oral intake was deferred and conservative management continued. A regular diet was started only after POD 28 endoscopy showed marked interval healing; 3-month follow-up confirmed complete mucosal healing. Contrast esophagography remains the standard postoperative assessment; nevertheless, this hypothesis-generating case suggests that, in carefully selected, clinically stable patients with high-risk anatomic features, low-insufflation carbon dioxide endoscopy may provide complementary structural information when feeding decisions remain uncertain after a negative contrast study.

Schlagwörter

Stichwörter der Autor:innen

Boerhaave syndromecarbon dioxidecontrast esophagographydehiscenceendoscopyesophageal perforation

Autor:innen und Institutionen

  • Department of Thoracic and Cardiovascular Surgery, CHA Bundang Medical Center, CHA University, 59 Yatap-ro, Bundang-gu, Seongnam-si 13496, Republic of Korea.

ORCID-Profile: Gong Min Rim

Zitieren

APA

Jung, H. S., Rim, G. M., Shim, Y. M., & Kim, K. W. (2026). Negative Contrast Esophagography Does Not Exclude Dehiscence After Boerhaave Repair: Complementary Low-Insufflation Carbon Dioxide Endoscopy. Diagnostics, 16(11), 1670. https://doi.org/10.3390/diagnostics16111670

Vancouver

Jung HS, Rim GM, Shim YM, Kim KW. Negative Contrast Esophagography Does Not Exclude Dehiscence After Boerhaave Repair: Complementary Low-Insufflation Carbon Dioxide Endoscopy. Diagnostics. 2026;16(11):1670. doi:10.3390/diagnostics16111670

BibTeX
@article{Jung2026,
  author = {Jung, Hee Suk and Rim, Gong Min and Shim, Young Mog and Kim, Kwan Wook},
  title = {Negative Contrast Esophagography Does Not Exclude Dehiscence After Boerhaave Repair: Complementary Low-Insufflation Carbon Dioxide Endoscopy},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {11},
  pages = {1670},
  doi = {10.3390/diagnostics16111670}
}
Kostenlos starten →