EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Fetal Fraction Optimized 106-Plex Digital PCR Assay for Non-Invasive Prenatal Testing of Fetal Trisomy

Songchang Chen, Xiaorui Luan, Xianling Cao, Cong Liu, Li Zhang, Wu Shang, Yiliang Zhang, Zhijie Yang, Chenming Xu iD

Diagnostics · 27.05.2026 · 16 (11) · 1642

DOI: 10.3390/diagnostics16111642 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 27.05.2026. Verfasst von Songchang Chen und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Reproduction and Development, Shanghai Key Laboratory of Reproduction and Development, Obstetrics and Gynecology Hospital, Fudan Univers…. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, National Key R&D Program of China, Shanghai Municipal Commission of Science and Technology Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Non-invasive prenatal testing (NIPT) for fetal aneuploidy requires accurate trisomy detection together with reliable fetal fraction assessment. This study evaluated the clinical feasibility of a 106-plex digital PCR (dPCR) NIPT assay for trisomies 13, 18, and 21 with internal fetal fraction quantification.

Methods

We consecutively recruited 470 women with high-risk singleton pregnancies. Fetal trisomies were detected using dPCR-NIPT and confirmed by invasive prenatal diagnosis. Pregnancies with negative prenatal diagnostic results were followed to birth. Analytical performance and quality control were assessed using trisomic DNA. The euploid cut-off and diagnostic performance were evaluated in two independent maternal plasma sample sets, using invasive diagnosis and clinical outcome as the reference standard. Results: dPCR-NIPT measured fetal fraction irrespective of fetal sex and detected trisomies at fetal fractions ≥3% using 5 ng DNA. A total of 12 of 470 plasma samples failed cell-free DNA quality control and were excluded before dPCR testing. Of the remaining 458 samples, 5 had fetal fractions below 3% and were classified as failed tests, yielding a nonreportable rate of 1.1%. Using a cut-off of 6.9 established in 103 training samples, no false-positive or false-negative trisomy calls were observed in the 350-sample testing set, corresponding to 100% sensitivity (95% confidence interval [CI], 85.18–100%) and 100% specificity (95% CI, 98.88–100%) for 23 confirmed trisomies.

Conclusions

This proof-of-principle study supports the feasibility of fetal fraction-informed dPCR-NIPT for trisomy detection in high-risk singleton pregnancies. Larger prospective studies in average-risk and earlier-gestation populations are required.

Schlagwörter

Stichwörter der Autor:innen

digital PCRfetal fractionhigh-risk singleton pregnancynon-invasive prenatal testingsuper-plextrisomy

Autor:innen und Institutionen

  • Institute of Reproduction and Development, Shanghai Key Laboratory of Reproduction and Development, Obstetrics and Gynecology Hospital, Fudan University, Shanghai 200437, China.
  • Shanghai Key Laboratory of Female Reproductive Endocrine Related Diseases, Shanghai 200090, China.
  • Nanjing Pregene Biotechnology, Nanjing 210047, China.

ORCID-Profile: Chenming Xu

Förderung

  • National Natural Science Foundation of China
  • National Key R&D Program of China
  • Shanghai Municipal Commission of Science and Technology Program
  • Shanghai Municipal Commission of Health and family planning

Zitieren

APA

Chen, S., Luan, X., Cao, X., Liu, C., Zhang, L., Shang, W., Zhang, Y., Yang, Z., & Xu, C. (2026). A Fetal Fraction Optimized 106-Plex Digital PCR Assay for Non-Invasive Prenatal Testing of Fetal Trisomy. Diagnostics, 16(11), 1642. https://doi.org/10.3390/diagnostics16111642

Vancouver

Chen S, Luan X, Cao X, Liu C, Zhang L, Shang W, et al. A Fetal Fraction Optimized 106-Plex Digital PCR Assay for Non-Invasive Prenatal Testing of Fetal Trisomy. Diagnostics. 2026;16(11):1642. doi:10.3390/diagnostics16111642

BibTeX
@article{Chen2026,
  author = {Chen, Songchang and Luan, Xiaorui and Cao, Xianling and Liu, Cong and Zhang, Li and Shang, Wu and Zhang, Yiliang and Yang, Zhijie and Xu, Chenming},
  title = {A Fetal Fraction Optimized 106-Plex Digital PCR Assay for Non-Invasive Prenatal Testing of Fetal Trisomy},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {11},
  pages = {1642},
  doi = {10.3390/diagnostics16111642}
}
Kostenlos starten →