Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 18.05.2026. Verfasst von Siti Nurwani Ahmad Ridzuan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Special Protein Unit, Specialized Diagnostic Centre, Institute for Medical Research, National Institutes of Health, Jalan Pahang, Kuala Lumpur 50588,…. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Internal quality control (IQC) data offers continuous insight into analytical performance under routine conditions. This study evaluated IQC practices and long-term analytical imprecision (CVa) across primary healthcare laboratories to derive analyte-specific reference change values (RCVs) for non-communicable disease (NCD) monitoring.

Methods

A 22-month retrospective analysis of IQC data was conducted across 29 primary healthcare laboratories using 32 analytical units (Beckman Coulter AU480) in Malaysian primary healthcare. Six analytes were assessed: glucose, creatinine, total cholesterol, triglycerides, HDL cholesterol, and ALT. CVa was estimated using median and 90th percentile (P90) coefficients of variation across two concentration levels. RCVs were calculated at 95% probability (Z = 1.96) by integrating observed CVa with within-subject biological variation (CVi) from EFLM databases.

Results

IQC testing was highly standardized (median: 20 measurements/month). Long-term data showed stable, concentration-dependent imprecision. Median CVa was lowest for glucose and lipids (1.7–1.9%) but higher for ALT (3.79%) and creatinine (3.52%) at Level 1. Derived RCV ranged from 14% (glucose) to 55.1% (triglycerides), with CVi being the dominant contributor to RCV magnitude for most analytes.

Conclusions

Long-term routine IQC data provide an analytically realistic foundation for deriving RCV in primary healthcare by reflecting real-world performance. Applying these RCV supports evidence-based interpretation of serial results, enhancing NCD monitoring by distinguishing true physiological change from analytical and biological noise.

Schlagwörter

Stichwörter der Autor:innen

analytical imprecisioninternal quality controlnon-communicable diseasesprimary healthcarereference change value

Autor:innen und Institutionen

  • Special Protein Unit, Specialized Diagnostic Centre, Institute for Medical Research, National Institutes of Health, Jalan Pahang, Kuala Lumpur 50588, Malaysia.
  • Alfa Diagnostik Sdn Bhd (Co. No. 1033482-X), No. 13, Jalan Delta U6/18, Taman Perindustrian Sunway Subang, Seksyen U6, Shah Alam 40150, Malaysia.

ORCID-Profile: Siti Nurwani Ahmad Ridzuan, Noor Hafizah Hassan, Nurul Izzati Hamzan

Zitieren

APA

Ahmad Ridzuan, S. N., Zamre, M. N., Shaari, F., Anuar, A. A. I., Hassan, N. H., & Hamzan, N. I. (2026). Analytical Imprecision and Reference Change Values for Longitudinal Monitoring of NCD-Related Biochemical Analytes. Diagnostics, 16(10), 1532. https://doi.org/10.3390/diagnostics16101532

Vancouver

Ahmad Ridzuan SN, Zamre MN, Shaari F, Anuar AAI, Hassan NH, Hamzan NI. Analytical Imprecision and Reference Change Values for Longitudinal Monitoring of NCD-Related Biochemical Analytes. Diagnostics. 2026;16(10):1532. doi:10.3390/diagnostics16101532

BibTeX
@article{AhmadRidzuan2026,
  author = {Ahmad Ridzuan, Siti Nurwani and Zamre, Muhammad Nursyazwan and Shaari, Fadzlyasraf and Anuar, Ahmad Asyraff Iqbal and Hassan, Noor Hafizah and Hamzan, Nurul Izzati},
  title = {Analytical Imprecision and Reference Change Values for Longitudinal Monitoring of NCD-Related Biochemical Analytes},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {10},
  pages = {1532},
  doi = {10.3390/diagnostics16101532}
}
Kostenlos starten →