EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fully Digital vs. Conventional Planning in Bimaxillary Orthognathic Surgery: Effects on 3D Accuracy and Surgical Efficiency

Petrică Florin Sava, Bogdan Radu Dragomir, Ilie Cristian Drochioi, Otilia Boișteanu, Andrei Nicolau iD, Daniela Șulea, Ștefan Gherasimescu, Victor Vlad Costan iD

Diagnostics · 30.04.2026 · 16 (9) · 1365

DOI: 10.3390/diagnostics16091365 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 30.04.2026. Verfasst von Petrică Florin Sava und 7 weiteren Autor:innen. Beteiligte Einrichtung: Grigore T. Popa University of Medicine and Pharmacy, 16 Universitatii Str., 700115 Iasi, Romania. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate transfer of the surgical plan is essential in bimaxillary orthognathic surgery, where small discrepancies between planned and postoperative skeletal positions may influence functional and aesthetic outcomes. This study compared the three-dimensional (3D) accuracy and time efficiency of conventional and fully digital planning workflows using CBCT-based evaluation.

Methods

This retrospective comparative study included 100 adult patients with skeletal Class II or III malocclusion treated by Le Fort I osteotomy combined with bilateral sagittal split osteotomy (BSSO). Patients were allocated to conventional planning (n = 50) or fully digital planning using IPS CaseDesigner (n = 50). Planned and postoperative CBCT datasets were superimposed using voxel-based cranial base registration. Linear deviations at A-point and Pogonion, total RMS error, planning time, and operative time were analyzed.

Results

Mean deviations were lower in the digital group at A-point (1.28 ± 0.28 mm vs. 1.63 ± 0.36 mm) and Pogonion (1.49 ± 0.42 mm vs. 1.95 ± 0.44 mm) (p < 0.001). Total RMS deviation was reduced in the digital workflow (1.39 ± 0.39 mm vs. 1.80 ± 0.54 mm; p < 0.001). Planning and operative times were significantly shorter in the digital group (p < 0.001). Moderate correlations were observed between time variables and 3D deviations.

Conclusions

Fully digital planning showed improved 3D accuracy and significantly reduced planning and operative times compared with conventional methods, while maintaining clinically acceptable deviations.

Schlagwörter

Stichwörter der Autor:innen

BSSOCBCTLe Fort I osteotomybimaxillary orthognathic surgerydigital surgical planningoperative timethree-dimensional accuracy

Autor:innen und Institutionen

  • Grigore T. Popa University of Medicine and Pharmacy, 16 Universitatii Str., 700115 Iasi, Romania.

ORCID-Profile: Andrei Nicolau, Victor Vlad Costan

Zitieren

APA

Sava, P. F., Dragomir, B. R., Drochioi, I. C., Boișteanu, O., Nicolau, A., Șulea, D., Gherasimescu, Ș., & Costan, V. V. (2026). Fully Digital vs. Conventional Planning in Bimaxillary Orthognathic Surgery: Effects on 3D Accuracy and Surgical Efficiency. Diagnostics, 16(9), 1365. https://doi.org/10.3390/diagnostics16091365

Vancouver

Sava PF, Dragomir BR, Drochioi IC, Boișteanu O, Nicolau A, Șulea D, et al. Fully Digital vs. Conventional Planning in Bimaxillary Orthognathic Surgery: Effects on 3D Accuracy and Surgical Efficiency. Diagnostics. 2026;16(9):1365. doi:10.3390/diagnostics16091365

BibTeX
@article{Sava2026,
  author = {Sava, Petrică Florin and Dragomir, Bogdan Radu and Drochioi, Ilie Cristian and Boișteanu, Otilia and Nicolau, Andrei and Șulea, Daniela and Gherasimescu, Ștefan and Costan, Victor Vlad},
  title = {Fully Digital vs. Conventional Planning in Bimaxillary Orthognathic Surgery: Effects on 3D Accuracy and Surgical Efficiency},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {9},
  pages = {1365},
  doi = {10.3390/diagnostics16091365}
}
Kostenlos starten →