EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

High-Frequency Miniprobe Endoscopic Ultrasonography Across the Gastrointestinal Tract

Francesco Bombaci, Angelo Bruni iD, Margherita Pavanato, Giuseppe Dell'Anna iD, Francesco Vito Mandarino iD, Giulio Calabrese, Andrea Lisotti iD, Pietro Fusaroli iD, Leonardo Henry Eusebi iD, Giovanni Barbara, Paolo Cecinato iD

Diagnostics · 28.04.2026 · 16 (9) · 1316

DOI: 10.3390/diagnostics16091316 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Diagnostics, online erschienen am 28.04.2026. Verfasst von Francesco Bombaci und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical and Surgical Sciences, University of Bologna, 40138 Bologna, Italy. Die Arbeit nennt 141 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Miniprobe endoscopic ultrasonography (mEUS) combines high-resolution imaging of the gastrointestinal (GI) wall and bile ducts with ease of applicability during routine endoscopy. This narrative review aims to provide an overview of known and emerging fields of application for mEUS in gastrointestinal endoscopy. After its initial development in pancreatobiliary scenarios in the early 1990s, mEUS has been recently reconsidered a third-space endoscopic technique that is progressively developing and spreading for the treatment of early gastrointestinal neoplastic lesions. The high spatial resolution of mEUS provides an accurate assessment of the degree of submucosal invasion in early esophageal, gastric, and colorectal neoplasia, while the small caliber of catheters allows for mEUS employment in settings where standard echoendoscopes are impractical (e.g., severe stenoses or proximal colonic lesions). Beyond cancer staging, mEUS offers point-of-care characterization of subepithelial lesions by defining the layer of origin and echo-pattern, eventually defining endoscopic resectability, but definitive diagnosis remains histological. In pancreatobiliary diseases, miniprobe intraductal ultrasonography (IDUS) shows its strongest application for indeterminate biliary strictures when endoscopic retrograde cholangiopancreatography (ERCP)-based sampling strategies and brushing cytology show inconclusive diagnoses, and in choledocholithiasis, particularly for the detection of small stones/sludge and confirmation of duct clearance. IDUS is also valuable for the staging of ampullary tumors, for longitudinal extension mapping in hilar cholangiocarcinoma and for selected portal biliopathy scenarios. Overall, mEUS and IDUS are high-resolution adjuncts that can meaningfully refine local decision-making in the treatment of superficial epithelial/subepithelial tumors or lesions involving the bile ducts. Limitations include shallow penetration, lack of tissue acquisition capability, a relative increase in post-ERCP pancreatitis risk for intraductal use, and substantial cost with limited availability in lower-volume centers.

Schlagwörter

Stichwörter der Autor:innen

endoscopy ultrasonographyhigh-frequency ultrasound catheter probesintraductal ultrasonographyminiprobe endoscopic ultrasonography

Autor:innen und Institutionen

  • Department of Medical and Surgical Sciences, University of Bologna, 40138 Bologna, Italy.
  • Gastroenterology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Hôpital Prive Armand Brillard, CEI Centre Endoscopie Interventionnelle, 94130 Paris, France.
  • Gastroenterology and Gastrointestinal Endoscopy Unit, IRCCS San Raffaele Hospital, 20132 Milan, Italy.
  • Gastroenterology and Gastrointestinal Endoscopy Division, IRCCS Policlinico San Donato, 20097 San Donato Milanese, Italy.
  • Gastroenterology Unit, San Pio Hospital, 82100 Benevento, Italy.

ORCID-Profile: Angelo Bruni, Giuseppe Dell'Anna, Francesco Vito Mandarino, Andrea Lisotti, Pietro Fusaroli, Leonardo Henry Eusebi, Paolo Cecinato

Zitieren

APA

Bombaci, F., Bruni, A., Pavanato, M., Dell'Anna, G., Mandarino, F. V., Calabrese, G., Lisotti, A., Fusaroli, P., Eusebi, L. H., Barbara, G., & Cecinato, P. (2026). High-Frequency Miniprobe Endoscopic Ultrasonography Across the Gastrointestinal Tract. Diagnostics, 16(9), 1316. https://doi.org/10.3390/diagnostics16091316

Vancouver

Bombaci F, Bruni A, Pavanato M, Dell'Anna G, Mandarino FV, Calabrese G, et al. High-Frequency Miniprobe Endoscopic Ultrasonography Across the Gastrointestinal Tract. Diagnostics. 2026;16(9):1316. doi:10.3390/diagnostics16091316

BibTeX
@article{Bombaci2026,
  author = {Bombaci, Francesco and Bruni, Angelo and Pavanato, Margherita and Dell'Anna, Giuseppe and Mandarino, Francesco Vito and Calabrese, Giulio and Lisotti, Andrea and Fusaroli, Pietro and Eusebi, Leonardo Henry and Barbara, Giovanni and Cecinato, Paolo},
  title = {High-Frequency Miniprobe Endoscopic Ultrasonography Across the Gastrointestinal Tract},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {9},
  pages = {1316},
  doi = {10.3390/diagnostics16091316}
}
Kostenlos starten →