EUVIMEDEUVIMED entdecken
KohortenstudieOpen Access · CC BY 4.0

Diagnostic Performance of Saline Infusion Sonography with Color Doppler Flow (SIS-CF) for Assessing Tubal Patency: A Prospective Cohort Study

Pantana Bangsomboon, Worashorn Lattiwongsakorn iD, Tawiwan Panthasri iD, Ubol Saeng-Anan, Usanee Sanmee iD, Natnita Mattawanon iD, Natpat Jansaka

Diagnostics · 24.04.2026 · 16 (9) · 1287

DOI: 10.3390/diagnostics16091287 ↗

Kurz gefasst

Kohortenstudie in der Zeitschrift Diagnostics, online erschienen am 24.04.2026. Verfasst von Pantana Bangsomboon und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Reproductive Medicine, Department of Obstetrics and Gynaecology, Faculty of Medicine, Chiang Mai University, Chiang Mai 50200, Thailand. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Faculty of medicine, Chiang Mai University, Chiang Mai University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Accurate evaluation of fallopian tube patency is an essential step in infertility assessment. This study investigated the diagnostic capability of saline infusion sonography combined with color Doppler flow (SIS-CF), using laparoscopic chromopertubation as the comparator method.

Methods

A prospective diagnostic accuracy study was conducted between January and November 2025 at the Infertility Unit, Chiang Mai University Hospital, Thailand. Women requiring laparoscopic assessment for infertility evaluation or preconception investigation were consecutively enrolled. Each participant underwent SIS-CF immediately before laparoscopic chromopertubation within the same operative session. Primary outcomes included diagnostic indices for tubal patency. Secondary outcomes included procedural duration and perioperative safety.

Results

Forty-four women (88 fallopian tubes) were included. SIS-CF demonstrated sensitivity of 89.4% (95% CI 78.1–95.9) and specificity of 95.5% (95% CI 77.2–99.9). Positive and negative predictive values were 98.3% and 75.0%, respectively. Likelihood ratios were 19.65 (positive) and 0.11 (negative), with overall accuracy of 90.9% (95% CI 82.9–95.8). Median procedure duration was 5.7 min for SIS-CF and 3.0 min for laparoscopic chromopertubation. No adverse events were recorded.

Conclusions

SIS-CF demonstrated favorable diagnostic characteristics for evaluation of tubal patency. The technique provided functional information regarding tubal status while maintaining a minimally invasive profile. Further investigation is warranted to determine its role within routine infertility workups.

Schlagwörter

Stichwörter der Autor:innen

chromopertubationcolor Doppler flowlaparoscopesaline infusion sonographytubal patency

Autor:innen und Institutionen

  • Division of Reproductive Medicine, Department of Obstetrics and Gynaecology, Faculty of Medicine, Chiang Mai University, Chiang Mai 50200, Thailand.

ORCID-Profile: Worashorn Lattiwongsakorn, Tawiwan Panthasri, Usanee Sanmee, Natnita Mattawanon

Förderung

  • Faculty of medicine, Chiang Mai University
  • Chiang Mai University

Zitieren

APA

Bangsomboon, P., Lattiwongsakorn, W., Panthasri, T., Saeng-Anan, U., Sanmee, U., Mattawanon, N., & Jansaka, N. (2026). Diagnostic Performance of Saline Infusion Sonography with Color Doppler Flow (SIS-CF) for Assessing Tubal Patency: A Prospective Cohort Study. Diagnostics, 16(9), 1287. https://doi.org/10.3390/diagnostics16091287

Vancouver

Bangsomboon P, Lattiwongsakorn W, Panthasri T, Saeng-Anan U, Sanmee U, Mattawanon N, et al. Diagnostic Performance of Saline Infusion Sonography with Color Doppler Flow (SIS-CF) for Assessing Tubal Patency: A Prospective Cohort Study. Diagnostics. 2026;16(9):1287. doi:10.3390/diagnostics16091287

BibTeX
@article{Bangsomboon2026,
  author = {Bangsomboon, Pantana and Lattiwongsakorn, Worashorn and Panthasri, Tawiwan and Saeng-Anan, Ubol and Sanmee, Usanee and Mattawanon, Natnita and Jansaka, Natpat},
  title = {Diagnostic Performance of Saline Infusion Sonography with Color Doppler Flow (SIS-CF) for Assessing Tubal Patency: A Prospective Cohort Study},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {9},
  pages = {1287},
  doi = {10.3390/diagnostics16091287}
}
Kostenlos starten →