Comparative Assessment of Proximal Humeral Bone Density Using CT Osteoabsorptiometry, Bone Microarchitecture Analysis, and a HU-Based Calibration Method: A CT and Micro-CT Study in Elderly Body Donors (65–86 Years)

Susanne Strasser iD, Lorenz Adam, Lukas Kampik, Rohit Arora, Johannes Dominikus Pallua iD

Diagnostics · 03.03.2026 · 16 (5) · 756

DOI: 10.3390/diagnostics16050756 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 03.03.2026. Verfasst von Susanne Strasser und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Medical University Innsbruck, 6020 Innsbruck, Austria. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Local bone quality of the proximal humerus is a key determinant of fracture risk and implant stability in osteoporotic bone. Beyond established HU-based calibration, CT-osteoabsorptiometry (CT-OAM)-derived indices and microarchitecture-oriented workflows warrant systematic cross-modality evaluation.

Methods

Twelve proximal humeral heads from six body donors (age 65–86 years; bilateral specimens) were analyzed using paired clinical CT and high-resolution micro-CT. Bone quality was quantified by (i) a HU-calibrated cancellous vBMD method (Krappinger et al.), (ii) a CT-OAM-inspired workflow reporting an ROI-averaged mean-intensity index in arbitrary units (a.u.), and (iii) a calibrated Bone Microarchitecture Analysis (BMA) workflow in Analyze 15.0. Paired tests, linear regression, and repeated-measures ANOVA after z-standardization were applied.

Results

HU calibration yielded a mean trabecular vBMD of 114.37 ± 35.15 mg/cm3 on clinical CT. The BMA workflow produced higher CT-based values (207.37 ± 23.78 mg/cm3, p < 0.001) and markedly higher micro-CT values (469.34 ± 30.99 a.u.), indicating a systematic level shift between calibration frameworks. The CT-OAM index averaged 166.94 ± 40.12 a.u. on clinical CT and 455.89 ± 132.63 a.u. on micro-CT. Cross-modality agreement was very strong for CT-OAM (R2 = 0.888) and moderate for BMA (R2 = 0.502). After z-standardization, no significant differences were detected between the three CT-based approaches.

Conclusions

A CT-OAM-inspired ROI-mean index and a BMA-based workflow provide complementary, transferable readouts of proximal humeral bone quality across clinical CT and micro-CT, with stronger cross-modality rank consistency for CT-OAM. Absolute density values differ systematically between calibration frameworks and should not be interpreted as directly interchangeable. These approaches support opportunistic, site-specific bone quality assessment from routine CT, but require prospective validation against fixation-related outcomes and robust scanner-independent standardization.

Schlagwörter

Stichwörter der Autor:innen

CT-osteoabsorptiometrybone microarchitecturebone mineral densitydiagnostic imagingmicro-CTosteoporosisproximal humerus

Autor:innen und Institutionen

  • Department of Orthopaedics and Traumatology, Medical University Innsbruck, 6020 Innsbruck, Austria.

ORCID-Profile: Susanne Strasser, Johannes Dominikus Pallua

Zitieren

APA

Strasser, S., Adam, L., Kampik, L., Arora, R., & Pallua, J. D. (2026). Comparative Assessment of Proximal Humeral Bone Density Using CT Osteoabsorptiometry, Bone Microarchitecture Analysis, and a HU-Based Calibration Method: A CT and Micro-CT Study in Elderly Body Donors (65–86 Years). Diagnostics, 16(5), 756. https://doi.org/10.3390/diagnostics16050756

Vancouver

Strasser S, Adam L, Kampik L, Arora R, Pallua JD. Comparative Assessment of Proximal Humeral Bone Density Using CT Osteoabsorptiometry, Bone Microarchitecture Analysis, and a HU-Based Calibration Method: A CT and Micro-CT Study in Elderly Body Donors (65–86 Years). Diagnostics. 2026;16(5):756. doi:10.3390/diagnostics16050756

BibTeX
@article{Strasser2026,
  author = {Strasser, Susanne and Adam, Lorenz and Kampik, Lukas and Arora, Rohit and Pallua, Johannes Dominikus},
  title = {Comparative Assessment of Proximal Humeral Bone Density Using CT Osteoabsorptiometry, Bone Microarchitecture Analysis, and a HU-Based Calibration Method: A CT and Micro-CT Study in Elderly Body Donors (65–86 Years)},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {5},
  pages = {756},
  doi = {10.3390/diagnostics16050756}
}