EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Aortoiliac Geometry on Non-Occlusive Thrombotic Risk Following Endovascular Repair of Abdominal Aortic Aneurysms

Jeong In Lee, Dac Hong An Ngo iD, Hong Pil Hwang, Young Min Han, Hyo Sung Kwak iD

Diagnostics · 24.08.2025 · 15 (17) · 2134

DOI: 10.3390/diagnostics15172134 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 24.08.2025. Verfasst von Jeong In Lee und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Jeonbuk National University, Jeonju 54907, Republic of Korea. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fund of Biomedical Research Institute, Jeonbuk National University Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study investigated the impact of aortoiliac geometry on thrombotic complication following aortic endovascular aneurysm repair (EVAR).

Methods

Data from 54 patients who received abdominal EVAR between January 2015 and December 2023, in which 18 developed unilateral iliac limb in-stent thrombus, were retrospectively reviewed. Clinical data, including cardiovascular risk factors, laboratory findings, and geometrical factors, including iliac diameter, sectional area, limb angles, and tortuosity, were collected. Aortoiliac geometry analyses were performed on the 3D model reconstructed from abdominal aortic computed tomography angiography (CTA) using semi-automated software (MIMICS version 25.0).

Results

Compared to non-thrombotic limbs, thrombotic iliac limbs showed larger maximum diameters (17.48 ± 0.95 mm vs. 14.14 ± 0.62 mm, p = 0.006), lower graft limb angles (117.52° ± 5.61° vs. 148.54° ± 4.31°, p < 0.001), lower aortoiliac angles (123.48° ± 4.66° vs. 141.96° ± 4.76°, p = 0.009), and higher iliac tortuosities (0.2 ± 0.03 vs. 0.12 ± 0.02, p = 0.02). Paired comparisons between normal and diseased limbs in 18 patients with thrombotic events also showed statistical differences in terms of iliac limb maximum diameter, graft limb angle, aortoiliac angle, and iliac tortuosity.

Conclusions

Thrombosis formation following EVAR in iliac limbs was associated with limb diameter, graft limb angle, aortoiliac angle, and tortuosity.

Schlagwörter

Stichwörter der Autor:innen

aortaendovascular aneurysm repairgeometryiliac arterythrombosis

Autor:innen und Institutionen

  • Department of Medicine, Jeonbuk National University, Jeonju 54907, Republic of Korea.
  • Department of Radiology, Research Institute of Clinical Medicine of Jeonbuk National University-Biomedical Research Institute of Jeonbuk National University Hospital, Jeonbuk National University and Medical School, Jeon…
  • Department of Radiology, Hue University of Medicine and Pharmacy, Hue 530000, Vietnam.
  • Department of Surgery, Jeonbuk National University Hospital, Jeonju 54907, Republic of Korea.

ORCID-Profile: Dac Hong An Ngo, Hyo Sung Kwak

Förderung

  • Fund of Biomedical Research Institute, Jeonbuk National University Hospital

Zitieren

APA

Lee, J. I., Ngo, D. H. A., Hwang, H. P., Han, Y. M., & Kwak, H. S. (2025). Influence of Aortoiliac Geometry on Non-Occlusive Thrombotic Risk Following Endovascular Repair of Abdominal Aortic Aneurysms. Diagnostics, 15(17), 2134. https://doi.org/10.3390/diagnostics15172134

Vancouver

Lee JI, Ngo DHA, Hwang HP, Han YM, Kwak HS. Influence of Aortoiliac Geometry on Non-Occlusive Thrombotic Risk Following Endovascular Repair of Abdominal Aortic Aneurysms. Diagnostics. 2025;15(17):2134. doi:10.3390/diagnostics15172134

BibTeX
@article{Lee2025,
  author = {Lee, Jeong In and Ngo, Dac Hong An and Hwang, Hong Pil and Han, Young Min and Kwak, Hyo Sung},
  title = {Influence of Aortoiliac Geometry on Non-Occlusive Thrombotic Risk Following Endovascular Repair of Abdominal Aortic Aneurysms},
  journal = {Diagnostics},
  year = {2025},
  volume = {15},
  number = {17},
  pages = {2134},
  doi = {10.3390/diagnostics15172134}
}
Kostenlos starten →