Consistency Analysis of Centiloid Values Across Three Commercial Software Platforms for Amyloid PET Quantification

Hyukjin Yoon iD, Narae Lee iD, Yoo Hyun Um iD, Woo Hee Choi iD

Diagnostics · 24.06.2025 · 15 (13) · 1599

DOI: 10.3390/diagnostics15131599 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 24.06.2025. Verfasst von Hyukjin Yoon und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Nuclear Medicine, Department of Radiology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-daero…. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Catholic Medical Center Research Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aimed to evaluate the consistency of Centiloid (CL) values calculated using three commercially available software platforms: BTXBrain (v1.1.2), MIM (v7.3.7), and SCALE PET (v2.0.1).

Methods

A total of 239 patients who underwent amyloid PET/CT with either F-18 flutemetamol (FMM) or F-18 florbetaben (FBB) were retrospectively analyzed. CL values were calculated using BTXBrain, MIM, and SCALE PET. Linear regression, Passing–Bablok regression, and Bland–Altman analysis were performed to assess the agreement between CL values. Subgroup analyses were conducted for each radiotracer. CL values were compared according to visual interpretation status.

Results

Strong correlations were observed between CL values derived from the three software platforms (R2 > 0.95). However, Passing–Bablok regression revealed significant proportional bias, with CL values from BTXBrain being lower than others, and CL values from SCALE PET being higher than others as CL values increased. Bland–Altman plots visualized the proportional bias, particularly between BTXBrain and SCALE PET. Subgroup analyses by radiotracer showed similar results. CL values in visually positive scans were significantly higher than those in visually negative scans across all platforms.

Conclusions

The three commercial software programs demonstrated high consistency in CL quantification. However, a notable systematic bias was observed. Further evaluation of various scanner effects and CL calculation methods is warranted to improve the consistency and reproducibility of CL quantification in clinical practice.

Schlagwörter

Stichwörter der Autor:innen

Alzheimer’s diseaseCentiloidPET

Autor:innen und Institutionen

  • Division of Nuclear Medicine, Department of Radiology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul 06591, Republic of Korea.
  • Department of Psychiatry, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul 06591, Republic of Korea.

ORCID-Profile: Hyukjin Yoon, Narae Lee, Yoo Hyun Um, Woo Hee Choi

Förderung

  • National Research Foundation of Korea
  • Catholic Medical Center Research Foundation

Zitieren

APA

Yoon, H., Lee, N., Um, Y. H., & Choi, W. H. (2025). Consistency Analysis of Centiloid Values Across Three Commercial Software Platforms for Amyloid PET Quantification. Diagnostics, 15(13), 1599. https://doi.org/10.3390/diagnostics15131599

Vancouver

Yoon H, Lee N, Um YH, Choi WH. Consistency Analysis of Centiloid Values Across Three Commercial Software Platforms for Amyloid PET Quantification. Diagnostics. 2025;15(13):1599. doi:10.3390/diagnostics15131599

BibTeX
@article{Yoon2025,
  author = {Yoon, Hyukjin and Lee, Narae and Um, Yoo Hyun and Choi, Woo Hee},
  title = {Consistency Analysis of Centiloid Values Across Three Commercial Software Platforms for Amyloid PET Quantification},
  journal = {Diagnostics},
  year = {2025},
  volume = {15},
  number = {13},
  pages = {1599},
  doi = {10.3390/diagnostics15131599}
}
Kostenlos starten →