EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Maternal BMI and Diagnostic Accuracy of Using Estimated Fetal Growth to Predict Abnormal Birthweight: Results from NICHD Fetal Growth Studies

Soutik Ghosal iD, Jessica L Gleason iD, Katherine L Grantz iD, Zhen Chen iD

Diagnostics · 31.05.2025 · 15 (11) · 1398

DOI: 10.3390/diagnostics15111398 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 31.05.2025. Verfasst von Soutik Ghosal und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Biostatistics, Public Health Science Department, School of Medicine, University of Virginia, Charlottesville, VA 22904, USA. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Division of Population Health Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: The objective of this study was to assess the diagnostic accuracy of sonographic estimated fetal weight (EFW) in predicting small (SGA)- or large-for-gestational-age (LGA) birthweight and examine whether the accuracy is associated with maternal body mass index (BMI).

Methods

The participants of NICHD Fetal Growth Studies with complete data on maternal BMI (10–13.9 weeks), EFW within 14 days of delivery (18–41.3 weeks), and birthweight were included in this study. Participants were categorized as normal (BMI 18.5–24.9 kg/m2) or overweight/obese (BMI > 24.9 to 44.9 kg/m2). EFW accuracy was evaluated using area under the Receiver Operating Characteristic curves (AUCs) for SGA and LGA classification, and EFW error was analyzed across BMI groups.

Results

Among 1289 women, 714 (55.4%) were in the normal BMI group. AUCs for LGA prediction were similar between BMI groups (0.77 ± 0.03 for normal vs. 0.79 ± 0.02 for overweight/obese, p = 0.593). However, for SGA, AUCs were higher in the overweight/obese group (.91 ± 0.01 vs. 0.84 ± 0.02, p = 0.004), indicating improved accuracy. EFW absolute and percent errors were comparable across BMI groups in the full, AGA, and LGA birth cohorts separately, but they trended lower (p = 0.12 and 0.15 for absolute and percent errors, respectively) in the overweight/obese group in the SGA birth cohort.

Conclusions

EFW has acceptable accuracy for predicting LGA, unaffected by BMI. However, for SGA, EFW accuracy is significantly higher in the overweight/obese group, suggesting that BMI influences diagnostic performance in SGA but not LGA classification.

Schlagwörter

Stichwörter der Autor:innen

BMIROC curveabnormal birthweight outcomesbiomarkersdiagnosis

Autor:innen und Institutionen

  • Division of Biostatistics, Public Health Science Department, School of Medicine, University of Virginia, Charlottesville, VA 22904, USA.
  • Division of Population Health Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, MD 20817, USA.

ORCID-Profile: Soutik Ghosal, Jessica L Gleason, Katherine L Grantz, Zhen Chen

Förderung

  • Division of Population Health Research

Zitieren

APA

Ghosal, S., Gleason, J. L., Grantz, K. L., & Chen, Z. (2025). Maternal BMI and Diagnostic Accuracy of Using Estimated Fetal Growth to Predict Abnormal Birthweight: Results from NICHD Fetal Growth Studies. Diagnostics, 15(11), 1398. https://doi.org/10.3390/diagnostics15111398

Vancouver

Ghosal S, Gleason JL, Grantz KL, Chen Z. Maternal BMI and Diagnostic Accuracy of Using Estimated Fetal Growth to Predict Abnormal Birthweight: Results from NICHD Fetal Growth Studies. Diagnostics. 2025;15(11):1398. doi:10.3390/diagnostics15111398

BibTeX
@article{Ghosal2025,
  author = {Ghosal, Soutik and Gleason, Jessica L and Grantz, Katherine L and Chen, Zhen},
  title = {Maternal BMI and Diagnostic Accuracy of Using Estimated Fetal Growth to Predict Abnormal Birthweight: Results from NICHD Fetal Growth Studies},
  journal = {Diagnostics},
  year = {2025},
  volume = {15},
  number = {11},
  pages = {1398},
  doi = {10.3390/diagnostics15111398}
}
Kostenlos starten →