EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Lung Ultrasound in Neonatal Respiratory Distress Syndrome: A Narrative Review of the Last 10 Years

Federico Costa iD, Annachiara Titolo iD, Mandy Ferrocino, Eleonora Biagi, Valentina Dell'Orto, Serafina Perrone iD, Susanna Esposito iD

Diagnostics · 12.12.2024 · 14 (24) · 2793

DOI: 10.3390/diagnostics14242793 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Diagnostics, online erschienen am 12.12.2024. Verfasst von Federico Costa und 6 weiteren Autor:innen. Beteiligte Einrichtung: Pediatric Clinic, Parma University Hospital, Department of Medicine and Surgery, University of Parma, 43126 Parma, Italy. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Neonatal respiratory distress syndrome (RDS) is a common and potentially life-threatening condition in preterm infants, primarily due to surfactant deficiency. Early and accurate diagnosis is critical to guide timely interventions such as surfactant administration and respiratory support. Traditionally, chest X-rays have been used for diagnosis, but lung ultrasound (LUS) has gained prominence due to its non-invasive, radiation-free, and bedside applicability. Compared to chest X-rays and CT scans, LUS demonstrates superior sensitivity and specificity in diagnosing RDS, particularly in identifying surfactant need and predicting CPAP failure. Additionally, LUS offers real-time imaging without radiation exposure, an advantage over other modalities. However, its broader adoption is limited by challenges in standardizing training, ensuring diagnostic reproducibility, and validating scoring systems, especially in resource-limited settings. This narrative review aims to evaluate the role of LUS in the diagnosis and management of neonatal RDS over the past decade, focusing on its clinical utility, scoring systems, and emerging applications. We reviewed the literature from 2013 to 2023, focusing on studies evaluating LUS’ diagnostic accuracy, scoring systems, and its potential role in guiding surfactant therapy and predicting CPAP failure. Despite its benefits, addressing the variability in operator expertise and integrating artificial intelligence to enhance usability are crucial for ensuring LUS’ efficacy across diverse clinical environments. Future research should prioritize standardizing training and scoring protocols to facilitate wider implementation and optimize neonatal respiratory care outcomes.

Schlagwörter

Stichwörter der Autor:innen

lung ultrasoundlung ultrasound scoreneonatesrespiratory distress syndromesurfactant therapy

Autor:innen und Institutionen

  • Pediatric Clinic, Parma University Hospital, Department of Medicine and Surgery, University of Parma, 43126 Parma, Italy.
  • Neonatology Unit, Parma University Hospital, Department of Medicine and Surgery, University of Parma, 43126 Parma, Italy.

ORCID-Profile: Federico Costa, Annachiara Titolo, Serafina Perrone, Susanna Esposito

Zitieren

APA

Costa, F., Titolo, A., Ferrocino, M., Biagi, E., Dell'Orto, V., Perrone, S., & Esposito, S. (2024). Lung Ultrasound in Neonatal Respiratory Distress Syndrome: A Narrative Review of the Last 10 Years. Diagnostics, 14(24), 2793. https://doi.org/10.3390/diagnostics14242793

Vancouver

Costa F, Titolo A, Ferrocino M, Biagi E, Dell'Orto V, Perrone S, et al. Lung Ultrasound in Neonatal Respiratory Distress Syndrome: A Narrative Review of the Last 10 Years. Diagnostics. 2024;14(24):2793. doi:10.3390/diagnostics14242793

BibTeX
@article{Costa2024,
  author = {Costa, Federico and Titolo, Annachiara and Ferrocino, Mandy and Biagi, Eleonora and Dell'Orto, Valentina and Perrone, Serafina and Esposito, Susanna},
  title = {Lung Ultrasound in Neonatal Respiratory Distress Syndrome: A Narrative Review of the Last 10 Years},
  journal = {Diagnostics},
  year = {2024},
  volume = {14},
  number = {24},
  pages = {2793},
  doi = {10.3390/diagnostics14242793}
}
Kostenlos starten →