Enhancing Radiologist Efficiency with AI: A Multi-Reader Multi-Case Study on Aortic Dissection Detection and Prioritization
Diagnostics · 28.11.2024 · 14 (23) · 2689
DOI: 10.3390/diagnostics14232689 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 28.11.2024. Verfasst von Martina Cotena und 10 weiteren Autor:innen. Beteiligte Einrichtung: Avicenna.AI, 375 Avenue du Mistral, 13600 La Ciotat, France. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background and Objectives: Acute aortic dissection (AD) is a life-threatening condition in which early detection can significantly improve patient outcomes and survival. This study evaluates the clinical benefits of integrating a deep learning (DL)-based application for the automated detection and prioritization of AD on chest CT angiographies (CTAs) with a focus on the reduction in the scan-to-assessment time (STAT) and interpretation time (IT). Materials and Methods: This retrospective Multi-Reader Multi-Case (MRMC) study compared AD detection with and without artificial intelligence (AI) assistance. The ground truth was established by two U.S. board-certified radiologists, while three additional expert radiologists served as readers. Each reader assessed the same CTAs in two phases: assessment unaided by AI assistance (pre-AI arm) and, after a 1-month washout period, assessment aided by device outputs (post-AI arm). STAT and IT metrics were compared between the two arms.
Results
This study included 285 CTAs (95 per reader, per arm) with a mean patient age of 58.5 years ±14.7 (SD), of which 52% were male and 37% had a prevalence of AD. AI assistance significantly reduced the STAT for detecting 33 true positive AD cases from 15.84 min (95% CI: 13.37–18.31 min) without AI to 5.07 min (95% CI: 4.23–5.91 min) with AI, representing a 68% reduction (p < 0.01). The IT also reduced significantly from 21.22 s (95% CI: 19.87–22.58 s) without AI to 14.17 s (95% CI: 13.39–14.95 s) with AI (p < 0.05).
Conclusions
The integration of a DL-based algorithm for AD detection on chest CTAs significantly reduces both the STAT and IT. By prioritizing urgent cases, the AI-assisted approach outperforms the standard First-In, First-Out (FIFO) workflow.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Avicenna.AI, 375 Avenue du Mistral, 13600 La Ciotat, France.
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1364 Clifton Road Northeast, Suite BG20, Atlanta, GA 30322, USA.
- Department of Radiological Sciences, University of California Irvine, Irvine, CA 92697, USA.
- Center for Artificial Intelligence in Diagnostic Medicine, University of California Irvine, Irvine, CA 92697, USA.
ORCID-Profile: Martina Cotena, Angela Ayobi, Brent D Weinberg, Peter D Chang, Mar Roca-Sogorb, Yasmina Chaibi, Sarah Quenet
Zitieren
APA
Cotena, M., Ayobi, A., Zuchowski, C., Junn, J. C., Weinberg, B. D., Chang, P. D., Chow, D. S., Soun, J. E., Roca-Sogorb, M., Chaibi, Y., & Quenet, S. (2024). Enhancing Radiologist Efficiency with AI: A Multi-Reader Multi-Case Study on Aortic Dissection Detection and Prioritization. Diagnostics, 14(23), 2689. https://doi.org/10.3390/diagnostics14232689
Vancouver
Cotena M, Ayobi A, Zuchowski C, Junn JC, Weinberg BD, Chang PD, et al. Enhancing Radiologist Efficiency with AI: A Multi-Reader Multi-Case Study on Aortic Dissection Detection and Prioritization. Diagnostics. 2024;14(23):2689. doi:10.3390/diagnostics14232689
BibTeX
@article{Cotena2024,
author = {Cotena, Martina and Ayobi, Angela and Zuchowski, Colin and Junn, Jacqueline C and Weinberg, Brent D and Chang, Peter D and Chow, Daniel S and Soun, Jennifer E and Roca-Sogorb, Mar and Chaibi, Yasmina and Quenet, Sarah},
title = {Enhancing Radiologist Efficiency with AI: A Multi-Reader Multi-Case Study on Aortic Dissection Detection and Prioritization},
journal = {Diagnostics},
year = {2024},
volume = {14},
number = {23},
pages = {2689},
doi = {10.3390/diagnostics14232689}
}
EUVIMED