Factors Influencing Background Parenchymal Enhancement in Contrast-Enhanced Mammography Images
Diagnostics · 08.10.2024 · 14 (19) · 2239
DOI: 10.3390/diagnostics14192239 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 08.10.2024. Verfasst von Daniel Wessling und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The aim of this study is to evaluate the correlation between background parenchymal enhancement (BPE) and various patient-related and technical factors in recombined contrast-enhanced spectral mammography (CESM) images. Material and Methods: We assessed CESM images from 62 female patients who underwent CESM between May 2017 and October 2019, focusing on factors influencing BPE. A total of 235 images, all acquired using the same mammography machine, were analyzed. A region of interest (ROI) with a standard size of 0.75 to 1 cm2 was used to evaluate the minimal, maximal, and average pixel intensity enhancement. Additionally, the images were qualitatively assessed on a scale from 1 (minimal BPE) to 4 (marked BPE). We examined correlations with body mass index (BMI), age, hematocrit, hemoglobin levels, cardiovascular conditions, and the amount of pressure applied during the examination.
Results
Our study identified a significant correlation between the amount of pressure applied during the examination and the BPE (Spearman’s ρ = 0.546). Additionally, a significant but weak correlation was observed between BPE and BMI (Spearman’s ρ = 0.421). No significant associations were found between BPE and menopausal status, cardiovascular preconditions, hematocrit, hemoglobin levels, breast density, or age.
Conclusions
Patient-related and procedural factors significantly influence BPE in CESM images. Specifically, increased applied pressure and BMI are associated with higher BPE.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany.
- Department of Diagnostic and Interventional Neuroradiology, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.
ORCID-Profile: Daniel Wessling, Ricarda Schwarz, Florian Hagen, Andreas Brendlin, Sebastian Gassenmaier
Zitieren
APA
Wessling, D., Männlin, S., Schwarz, R., Hagen, F., Brendlin, A., Gassenmaier, S., & Preibsch, H. (2024). Factors Influencing Background Parenchymal Enhancement in Contrast-Enhanced Mammography Images. Diagnostics, 14(19), 2239. https://doi.org/10.3390/diagnostics14192239
Vancouver
Wessling D, Männlin S, Schwarz R, Hagen F, Brendlin A, Gassenmaier S, et al. Factors Influencing Background Parenchymal Enhancement in Contrast-Enhanced Mammography Images. Diagnostics. 2024;14(19):2239. doi:10.3390/diagnostics14192239
BibTeX
@article{Wessling2024,
author = {Wessling, Daniel and Männlin, Simon and Schwarz, Ricarda and Hagen, Florian and Brendlin, Andreas and Gassenmaier, Sebastian and Preibsch, Heike},
title = {Factors Influencing Background Parenchymal Enhancement in Contrast-Enhanced Mammography Images},
journal = {Diagnostics},
year = {2024},
volume = {14},
number = {19},
pages = {2239},
doi = {10.3390/diagnostics14192239}
}
EUVIMED