EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Prognostic Value of Optic Nerve Sheath Diameters after Acute Ischemic Stroke According to Slice Thickness on Computed Tomography

Han-Bin Lee, Sang Hoon Oh iD, Jinhee Jang, Jaseong Koo iD, Hyo Jin Bang, Min Hwan Lee iD

Diagnostics · 12.08.2024 · 14 (16) · 1754

DOI: 10.3390/diagnostics14161754 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 12.08.2024. Verfasst von Han-Bin Lee und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Catholic Medical Center Research Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The optic nerve sheath diameter (ONSD) can predict intracranial pressure and outcomes in neurological disease, but it remains unclear whether a small ONSD can be accurately measured on routine CT images with a slice thickness of approximately 4–5 mm. We measured the ONSD and ONSD/eyeball transverse diameter (ETD) ratio on routine-slice (4 mm) and thin-slice (0.6–0.75 mm) brain CT images from initial scans of acute ischemic stroke (AIS) patients. ONSD-related variables, National Institutes of Health Stroke Scale (NIHSS) scores, and age were compared between good (modified Rankin Scale [mRS] ≤ 2) and poor (mRS > 2) outcomes at discharge. Among 155 patients, 38 had poor outcomes. The thin-slice ONSD was different between outcome groups (p = 0.047), while the routine-slice ONSD showed no difference. The area under the curve (AUC) values for the ONSD and ONSD/ETD were 0.58 (95% CI, 0.49–0.66) and 0.58 (95% CI, 0.50–0.66) on the routine-slice CT, and 0.60 (95% CI, 0.52–0.68) and 0.62 (95% CI, 0.54–0.69) on the thin-slice CT. The thin-slice ONSD/ETD ratio correlated with initial NIHSS scores (r = 0.225, p = 0.005). After adjusting for NIHSS scores and age, ONSD-related variables were not associated with outcomes, and adding them to a model with NIHSS scores and age did not improve performance (all p-values > 0.05). Although ONSD measurements were not an independent outcome predictor, they correlated with stroke severity, and the thin-slice ONSD provided a slightly better prognostic performance than the routine-slice ONSD.

Schlagwörter

Stichwörter der Autor:innen

acute ischemic strokecomputed tomographyneurological outcomeoptic nerve sheath diameter

Autor:innen und Institutionen

  • Department of Neurology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.
  • Department of Emergency Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.
  • Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.

ORCID-Profile: Sang Hoon Oh, Jaseong Koo, Min Hwan Lee

Förderung

  • Catholic Medical Center Research Foundation

Zitieren

APA

Lee, H. B., Oh, S. H., Jang, J., Koo, J., Bang, H. J., & Lee, M. H. (2024). Prognostic Value of Optic Nerve Sheath Diameters after Acute Ischemic Stroke According to Slice Thickness on Computed Tomography. Diagnostics, 14(16), 1754. https://doi.org/10.3390/diagnostics14161754

Vancouver

Lee HB, Oh SH, Jang J, Koo J, Bang HJ, Lee MH. Prognostic Value of Optic Nerve Sheath Diameters after Acute Ischemic Stroke According to Slice Thickness on Computed Tomography. Diagnostics. 2024;14(16):1754. doi:10.3390/diagnostics14161754

BibTeX
@article{Lee2024,
  author = {Lee, Han-Bin and Oh, Sang Hoon and Jang, Jinhee and Koo, Jaseong and Bang, Hyo Jin and Lee, Min Hwan},
  title = {Prognostic Value of Optic Nerve Sheath Diameters after Acute Ischemic Stroke According to Slice Thickness on Computed Tomography},
  journal = {Diagnostics},
  year = {2024},
  volume = {14},
  number = {16},
  pages = {1754},
  doi = {10.3390/diagnostics14161754}
}
Kostenlos starten →