EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Relationship between Volpara Density Grade and Compressed Breast Thickness in Japanese Patients with Breast Cancer

Mio Adachi, Toshiyuki Ishiba iD, Sakiko Maruya, Kumiko Hayashi, Yuichi Kumaki, Goshi Oda iD, Tomoyuki Aruga iD

Diagnostics · 31.07.2024 · 14 (15) · 1651

DOI: 10.3390/diagnostics14151651 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 31.07.2024. Verfasst von Mio Adachi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery (Breast), Tokyo Metropolitan Cancer and Infectious Disease Center Komagome Hospital, Tokyo 113-8677, Japan. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

High breast density found using mammographs (MGs) reduces positivity rates and is considered a risk factor for breast cancer. Research on the relationship between Volpara density grade (VDG) and compressed breast thickness (CBT) in the Japanese population is still lacking. Moreover, little attention has been paid to pseudo-dense breasts with CBT < 30 mm among high-density breasts. We investigated VDG, CBT, and apparent high breast density in patients with breast cancer.

Methods

Women who underwent MG and breast cancer surgery at our institution were included. VDG and CBT were measured. VDG was divided into a non-dense group (NDG) and a dense group (DG).

Results

This study included 419 patients. VDG was negatively correlated with CBT. The DG included younger patients with lower body mass index (BMI) and thinner CBT. In the DG, patients with CBT < 30 mm had lower BMI and higher VDG; however, no significant difference was noted in the positivity rate of the two groups.

Conclusions

Younger women tend to have higher breast density, resulting in thinner CBT, which may pose challenges in detecting breast cancer on MGs. However, there was no significant difference in the breast cancer detection rate between CBT < 30 mm and CBT ≥ 30 mm.

Schlagwörter

Stichwörter der Autor:innen

Volparabreast densitycompressed breast thicknessdense breastpseudo-dense breast

Autor:innen und Institutionen

  • Department of Surgery (Breast), Tokyo Metropolitan Cancer and Infectious Disease Center Komagome Hospital, Tokyo 113-8677, Japan.
  • Department of Breast Surgery, Tokyo Medical and Dental University, Tokyo 113-8510, Japan.

ORCID-Profile: Toshiyuki Ishiba, Goshi Oda, Tomoyuki Aruga

Zitieren

APA

Adachi, M., Ishiba, T., Maruya, S., Hayashi, K., Kumaki, Y., Oda, G., & Aruga, T. (2024). Relationship between Volpara Density Grade and Compressed Breast Thickness in Japanese Patients with Breast Cancer. Diagnostics, 14(15), 1651. https://doi.org/10.3390/diagnostics14151651

Vancouver

Adachi M, Ishiba T, Maruya S, Hayashi K, Kumaki Y, Oda G, et al. Relationship between Volpara Density Grade and Compressed Breast Thickness in Japanese Patients with Breast Cancer. Diagnostics. 2024;14(15):1651. doi:10.3390/diagnostics14151651

BibTeX
@article{Adachi2024,
  author = {Adachi, Mio and Ishiba, Toshiyuki and Maruya, Sakiko and Hayashi, Kumiko and Kumaki, Yuichi and Oda, Goshi and Aruga, Tomoyuki},
  title = {Relationship between Volpara Density Grade and Compressed Breast Thickness in Japanese Patients with Breast Cancer},
  journal = {Diagnostics},
  year = {2024},
  volume = {14},
  number = {15},
  pages = {1651},
  doi = {10.3390/diagnostics14151651}
}
Kostenlos starten →