Glaucoma Detection through a Novel Hyperspectral Imaging Band Selection and Vision Transformer Integration
Diagnostics · 18.06.2024 · 14 (12) · 1285
DOI: 10.3390/diagnostics14121285 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 18.06.2024. Verfasst von Ching-Yu Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi 62247, Taiwan. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council of The Republic of China, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation-National Chung Cheng University Joint Research Program, National Science and Technology Council, the Republic of China.
Abstract (Originalsprache)
Conventional diagnostic methods for glaucoma primarily rely on non-dynamic fundus images and often analyze features such as the optic cup-to-disc ratio and abnormalities in specific retinal locations like the macula and fovea. However, hyperspectral imaging techniques focus on detecting alterations in oxygen saturation within retinal vessels, offering a potentially more comprehensive approach to diagnosis. This study explores the diagnostic potential of hyperspectral imaging for glaucoma by introducing a novel hyperspectral imaging conversion technique. Digital fundus images are transformed into hyperspectral representations, allowing for a detailed analysis of spectral variations. Spectral regions exhibiting differences are identified through spectral analysis, and images are reconstructed from these specific regions. The Vision Transformer (ViT) algorithm is then employed for classification and comparison across selected spectral bands. Fundus images are used to identify differences in lesions, utilizing a dataset of 1291 images. This study evaluates the classification performance of models using various spectral bands, revealing that the 610–780 nm band outperforms others with an accuracy, precision, recall, F1-score, and AUC-ROC all approximately at 0.9007, indicating its superior effectiveness for the task. The RGB model also shows strong performance, while other bands exhibit lower recall and overall metrics. This research highlights the disparities between machine learning algorithms and traditional clinical approaches in fundus image analysis. The findings suggest that hyperspectral imaging, coupled with advanced computational techniques such as the ViT algorithm, could significantly enhance glaucoma diagnosis. This understanding offers insights into the potential transformation of glaucoma diagnostics through the integration of hyperspectral imaging and innovative computational methodologies.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi 62247, Taiwan.
- Department of Mechanical Engineering, National Chung Cheng University, Chiayi 62102, Taiwan.
- Department of Optometry, Central Taiwan University of Science and Technology, No. 666, Buzih Road, Taichung City 406053, Taiwan.
- School of Nursing, Shinawatra University, 99 Moo 10, Bangtoey, Samkhok, Pathum Thani 12160, Thailand.
- Center for Innovative Research on Aging Society (CIRAS), National Chung Cheng University, 168, University Rd., Min Hsiung, Chiayi 62102, Taiwan.
- Department of Ophthalmology, Kaohsiung Armed Forces General Hospital, 2, Zhongzheng 1st. Rd., Kaohsiung City 80284, Taiwan.
ORCID-Profile: Ching-Yu Wang, Hsiang-Chen Wang
Förderung
- National Science and Technology Council of The Republic of China
- Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation-National Chung Cheng University Joint Research Program
- National Science and Technology Council, the Republic of China
- Dalin Tzu Chi Hospital
- Kaohsiung Armed Forces General Hospital
Zitieren
APA
Wang, C. Y., Nguyen, H. T., Fan, W. S., Lue, J. H., Saenprasarn, P., Chen, M. M., Huang, S. Y., Lin, F. C., & Wang, H. C. (2024). Glaucoma Detection through a Novel Hyperspectral Imaging Band Selection and Vision Transformer Integration. Diagnostics, 14(12), 1285. https://doi.org/10.3390/diagnostics14121285
Vancouver
Wang CY, Nguyen HT, Fan WS, Lue JH, Saenprasarn P, Chen MM, et al. Glaucoma Detection through a Novel Hyperspectral Imaging Band Selection and Vision Transformer Integration. Diagnostics. 2024;14(12):1285. doi:10.3390/diagnostics14121285
BibTeX
@article{Wang2024,
author = {Wang, Ching-Yu and Nguyen, Hong-Thai and Fan, Wen-Shuang and Lue, Jiann-Hwa and Saenprasarn, Penchun and Chen, Meei-Maan and Huang, Shuan-Yu and Lin, Fen-Chi and Wang, Hsiang-Chen},
title = {Glaucoma Detection through a Novel Hyperspectral Imaging Band Selection and Vision Transformer Integration},
journal = {Diagnostics},
year = {2024},
volume = {14},
number = {12},
pages = {1285},
doi = {10.3390/diagnostics14121285}
}
EUVIMED